Please refer to the following sheet for detailed information.

Parameter Function

Event
Type

There are three types: Motion detection/video loss/Camera Masking.

Channel

Select channel name from the dropdown list.

Enable

You need to draw a circle to enable motion detection function.

Sensitivity There are six levels. The sixth level has the highest sensitivity.

Region

z

There are six levels. The sixth level has the highest sensitivity.

z

Region: If you select motion detection type, you can click this button
to set motion detection zone. The interface is shown as in Figure 7-
43. There are PAL 22X18/NTSC 22X15 zones. Right click mouse
you can go to full-screen display mode. Do remember clicking OK
button to save your motion detection zone setup.

Period

z

Motion detection function becomes activated in the specified
periods.

z

There are six periods in one day. Please draw a circle to enable
corresponding period.

z

Select date. If you do not select, current setup applies to today only.
You can select all week column to apply to the whole week.

z

Click OK button, system goes back to motion detection interface;
please click save button to exit.

Anti-dither System only memorizes one event during the anti-dither period. The

value ranges from 3s to 600s.

Normal
out

z

There is 2-channel alarm output.

z

Corresponding to motion detection alarm output port(multiple
choices)

z

Enable alarm activation function. You need to select alarm output
port so that system can activate corresponding alarm device when
alarm occurs.