Quick-Check User Instructions

15

Temp

Press this softkey to choose the source of the temperature reading, the
Quick-Check itself (Meter), outside input (Input) or None. If you choose
Input, you are prompted to enter the temperature. When finished, press
the Enter softkey to accept this value.

Next you are prompted to choose Fahrenheit or Centigrade as the
temperature unit. When your choice is highlighted, press the Enter
softkey.

An annunciator shows when temperature has been manually entered. See
example below:

Temperature Display Mode

Auto-off can preserve battery life.

Setup

Press the Setup softkey and you will see these choices; Off, PtFmt, Misc,
About, and Test. These are described below:

Off

Press this softkey to enable or disable the auto-shutdown function.
If you choose Yes, you are asked to set a period of time in
minutes. Next, press the Enter softkey to accept this value. You
are then asked to set the shutdown type; Fixed, No Load, or No
Change. These are described below;

Fixed - The unit will shutdown after the set number of minutes no
matter what happens.

No Load - The unit will shutdown after the set number of minutes
only if there is no load on the unit. This prevents shutdown in the
middle of a test.

No Change - The unit will shutdown if there has been no keypad
activity or change in tension after the set number of minutes.

PtFmt Not currently used.

Misc

Press this softkey to set the following:

Flash - Enables or disables the momentary blinking of the display
to acknowledge a key press.

Zero - Enables the use of the Zero softkey to clear a peak tension
value.

Contr - Press this key to adjust the contrast of the LCD display.
Press the Up soft key to lighten the contrast. Press the Down
softkey to darken the contrast.