15 system alarms – CANOGA PERKINS 2340 Universal Fiber Optic Modem User Manual
Page 40

Model 2340 Model User Manual
4-16
4.15 System
Alarms
The System Alarms screen reports alarms and faults on the local 2340 and the remote 2340. See
Figure 20 and Table 19. To view current alarm status, follow these steps:
1. From the Main Menu, type 5, Alarms, and press
2. To return to the Main Menu, press
------------------------------SYSTEM ALARMS-------------------------------
Local Remote
Modem Redundancy Status N/A N/A
Configuration Errors No No
Fiber Loss of Signal No No
Electrical Loss of Signal No No
SQL Rx OK OK
Chassis Management N/A N/A
Alarm Relay Inputs N/A N/A
Power Supply Primary OK OK
Power Supply Secondary N/A N/A
Fan N/A N/A
Power-On Self Test OK OK
Figure 20. System Alarms Screen
Table 19. System Alarms Definitions
Item Definition
Modem Redundancy
Status
Reports if redundancy is Active, Inactive, or turned off (N/A)
Configuration Errors
Check that the local and remote modems have compatible set ups,
including software version
Fiber Loss of Signal
Checks if optical loss of signal errors
Electrical Loss of Signal When LOS detection is On, checks if electrical loss of signal occurs
SQL Rx
Checks if squelch occurs
Chassis Management
Reports OK if 2340 is in UCS 1000 with DMM or N/A if 2340 is in
1040, 1050, or UCS 1001
Alarm Relay Inputs
Reports Loss if CLS occurs or OK if signal is good; UCS 1001, only
Power Supply Primary
Reports function of main power supply
Power Supply Secondary Reports function of second power supply
Fan
Reports fan failure
Power-On Self Test
Reports OK or faulty hardware or software