3.6
L134, L135, L136, L137: T1 and E1
The L134, L135, L136, and L137 ELIMs are electrically compatible with T1 or E1 specifications.
Tables 6 and 7 show the connector pinouts.
• L134 supports T1 and transmits AMI or B8ZS code. The ELIM includes an RJ-45 connector; use
a 100 ohm twisted pair cable to connect to the local network equipment.
• L135 supports T1 and transmits AMI or B8ZS code. The ELIM includes a DA-15 connector; use
a 100 ohm twisted pair cable to connect to the local network equipment.
• L136 supports E1 and transmits AMI or HDB3 code. The ELIM includes an RJ-45 connector;
use a 120 ohm twisted pair cable to connect to the local network equipment.
• L137 supports E1 and transmits AMI or HDB3 code. The ELIM includes a DA-15 connector;
use a 120 ohm twisted pair cable to connect to the local network equipment.
These ELIMs include two LEDs, LOS and AIS. See Table 8.
Table 6. RJ-48 Pinout
Pin Direction
1, 2
Tx (Output)
4, 5
Rx (Input)
Table 7. DA-15 Pinout
Pin Direction
1, 9
Rx (Input)
3, 11
Tx (Output)
Table 8. T1 and E1 ELIM Status LEDs
LED Color
Description
LOS Off
Normal
Red
Loss of received signal
AIS Off
Normal
Amber
Alarm; receiving all 1s