Model 2340 Model User Manual

4-8

ELIM Group

Parameter

Possible Values

L130 with
P53

Interface Type

P53

Operating Mode

Internal, Ext. Station, or External

Internal

Rate

(bps)

(select for Internal Mode)

Type the rate, then confirm the rate
calculated from the Rate equation above

Delay

(ns)

(select for Internal Rate)

0 to 170 in 10 ns increments

TD

Timing

(select for Ext. Station or
External Modes)

SCTE or SCTE Sampled

DCD

Output

(select for External Mode)

Remote RTS or CLS (DCDFalse if CLS
is True)

RLSD

(select for External Mode)

Normal, +6V/GND, +6V/-6V, GND/-6V,
GND/+6V, -6V/+6V, or -6V/GND

DSR Off When
(select for External Mode)

Far Local Test or Any Test On

L131, L132, and L138
TwinAx 422 or DC-37
High Speed EIA-422

All values preset

L133
TTL/BNC

Operating Mode

Internal, Slave, External, or
Asynchronous

Internal

Rate

(bps)

(select for Internal Mode)

Type the rate, then confirm the rate
calculated from the Rate equation above

TD

Timing

(select for Internal, Slave, or
External Modes)

Internal Mode: SCTE, SCT, or SCT
Inverted
Slave Mode: SCTE, SCTE Sampled,
SCT, or SCT Inverted
External Mode: SCTE or SCTE sampled

RD

Timing

(select for External Mode)

SCT or SCR

L134, L135, L136, and
L137
Transparent T1/E1

E1: All values preset
T1: Set only T1 Output


0-133FT, 133-266FT, 266-399FT,
399-533FT, 533-655FT, CSU part 68
opt. A, or CSU T1C1.2

4.8 Trap

Configuration

Traps are messages that require management attention and are routed to the Network Manager, but do
not trigger alarms. Use the Trap Configuration screen to view the current configuration and to enable
or disable traps for the 2340. See Figure 13 and Table 14. To configure traps, follow these steps:

1. From the System Configuration menu type 3, "Trap Configuration," and press .