Silver crown plus pilot’s guide – BendixKing SILVER CROWN PLUS System SILVER CROWN PLUS User Manual
Page 58
![background image](/manuals/651214/58/background.png)
Silver Crown Plus Pilot’s Guide
54
lighted displays that may be in the
cockpit. The display is adjusted in the
test (TST) mode.
To manually adjust the display
brightness, perform the following
operations:
1. Turn the Function Selector Knob
to "TST".
2. Turn the BRT knob clockwise to
increase the display brightness,
or counterclockwise to decrease
the display brightness.
The eight carets below the
alphanumeric display characters
indicate the brightness setting
(relative to the photocell reading).
Maximum brightness is indicated by
all eight carets being illuminated.
Minimum brightness is indicated by no
carets being illuminated. The factory
default setting is represented by four
carets being illuminated. Pressing the
IDT button will return the brightness to
the default factory value.
3. Turn the Function Selector Knob
from TST to store the display
brightness settings.
NOTE: If power is removed from the
KT 73 while still in the test mode, the
brightness setting will be lost and the
unit will revert to the last known
setting.
- KY 196A System SILVER CROWN PLUS KX 165A System SILVER CROWN PLUS KX 155A System SILVER CROWN PLUS KT 76C System SILVER CROWN PLUS KT 73 System SILVER CROWN PLUS KT 71 System SILVER CROWN PLUS KT 70 System SILVER CROWN PLUS KN 64 System SILVER CROWN PLUS KN 62A System SILVER CROWN PLUS KN 53 System SILVER CROWN PLUS KMA 30 System SILVER CROWN PLUS KMA 28 System SILVER CROWN PLUS KMA 26 System SILVER CROWN PLUS