beautypg.com

BendixKing KPA 900 System RDR-2000 User Manual

Page 25

background image

BENDIX/KING®

KPA 900

Page 3-5

Revision 2

©Honeywell International Inc. Do not print without express permission of Honeywell.

Dec/2007

3.3.5.3.2 TOOLS

→ WRITE TO CM 2000

WARNING: WRITING TO THE CM 2000 OVERWRITES EXISTING DATA. IF A CM

2000 FROM AN EXISTING INSTALLATION IS CHANGED, YOU MAY
WANT TO READ THE MODULE BEFORE MODIFYING IT, INSTEAD OF
LOADING THE DEFAULT CONFIGURATION FILE AND STARTING
AGAIN. THIS IS ESPECIALLY TRUE IF THE INSTALLATION IS FOR AN
ART, AS THE STABILIZATION CALIBRATION DATA IS LOST WITH
THE DEFAULT FILE BUT KEPT WITH A MODULE READ.

This option transfers the unit parameters displayed on the KPA 900 to the CM 2000. A
progress meter is displayed during the write operation. The activity log is updated with the
status of the operation when it is complete. A successful programming operation issues a
log statement as follows: "CM 2000 read and verified to be in agreement with KPA 900
displayed parameters."

3.3.5.3.3 VIEW/EDIT ART STAB

This option opens a window that allows the stabilization calibration for the ART 2000 and
ART 2100 to be viewed and calibrated. Refer to Section 3.6.8 for details of operation.

3.3.5.3.4 TOOLS

→ TEST → VALIDATE CM 2000

This option opens a window that allows a quick test of the operation of the CM 2000. The
test checks that the module is working and contains the correct data. It is intended as a
field tool to isolate the cause of a displayed CM fault. It also provides a synopsis of the
configuration data as an aid to troubleshoot a problematic installation. Refer to Section
3.6.6 for details of operation.

3.3.5.3.5 TOOLS

→ TEST → FACTORY TEST

This option opens a window that performs the factory test for the CM 2000. This is the test
procedure used by Honeywell manufacturing before the CM 2000 is shipped. The test is
time consuming, but may be used in the field, if desired. Refer to Section 3.6.7 for details
of operation.

3.3.5.3.6 TOOLS

→ RESTART

This option clears the activity log and reverses any changes that have not been
programmed into the CM 2000.

This manual is related to the following products: