3.3.5.1.4 FILE
→ SAVE LOG FILE
This option saves the contents of the activity log to a file. This option is useful to an OEM
who needs a record for quality purposes. Refer to Section 3.6.4 for details of operation.
3.3.5.1.5 FILE
→ EXIT
This option shuts down the KPA 900 and releases the memory back to Windows. This is
the preferred method to exit the program, due to the memory operation. The window close
button retains the memory allocation until the next computer restart. The KPA 900 has a
very small memory requirement, so this is not a significant concern for most modern
computers.
3.3.5.2 UNIT TYPE MENU
3.3.5.2.1 UNIT TYPE
→ ART 2000
UNIT TYPE
→ ART 2100
UNIT TYPE
→ KRA 405B
This option opens the Unit Parameter Editor frame for the selected unit type. Unlike
previous versions of the KPA 900 software, the unit type selection is not required before
reading the CM 2000. The unit type can also be changed without exiting the program.
Changing the unit type or reading a module programmed with a different unit type causes
the KPA 900 to issue a warning before changing the Unit Parameter Editor. Refer to
Section 3.4 for details of operation.
3.3.5.3 TOOLS MENU
3.3.5.3.1 TOOLS
→ READ FROM CM 2000
This option transfers the configuration data contained in the CM 2000 to the unit
parameters displayed on the KPA 900. A progress meter is displayed during the read
operation. The activity log is updated with the status of the operation when it is complete.