30
purposes. A Beat Frequency
Oscillator (BFO) function is provided to
permit these stations to be more easily
identified. Placing the function switch
in either of the BFO positions causes a
1000Hz tone to be heard whenever
there is a radio carrier signal present
at the selected frequency.
Frequency Control
A. Standby Entry
The Standby frequency is read on
the bottom of the display. It may
be tuned by turning the frequency
selector control. Standby
frequency tuning does not affect
the Active frequency. Depressing
the Transfer button causes the
Standby frequency to appear in the
Active, or upper frequency location.
To tune Standby frequency:
1. Tune frequency of station
desired.
2. Push Transfer button
This method permits the pilot to
tune to the desired frequency
without the accompanying noise of
tuning through other stations.
B. Active Entry
The Active frequency is read on
the top of the display. Holding the
transfer button depressed for
approximately 2 seconds causes
the Standby frequency display to
go out. The Active frequency may
now be controlled directly by the
frequency selector control. In this
tuning mode, the station audio is
present, permitting the operator to
hunt for a station by listening to the
audio while tuning. The large outer
knob of the frequency selector
control selects the 100's KHz from
1 to 17, with roll over from 17 to 1,
and roll under from 1 to 17. The
small inner knob selects 10's KHz
when pushed in and 1's KHz when
pulled out. The 10's KHz and 1's
KHz rolls over from 9 to 0 and rolls
under from 0 to 9.
C. Display Flash
Any time the frequency displayed
is below 190, the display flashes.
This is to alert the pilot he has
selected an out of band frequency.
D. X Character
The small X to the right of the
active frequency turns off in the
ADF and ADF/BFO modes only
when the ADF is pointing.
KFS 586A Control Functions
ADF
VOL
OFF
S
B
Y
X
1799
388
CHAN
PUSH
MODE
ACTIVE WINDOW
STANDBY WINDOW
OFF/ON/MODE
VOLUME
CHANNEL BUTTON
NON-ACTIVE RECEIVE
ANNUNCIATOR
TRANSFER BUTTON
FREQUENCY
CONTROL KNOBS
ı
- KTU 709 KTR 908 KNR 634/634A KNI 582 KFS 598/598A KFS 586/586A KFS 579A KFS 576/576A KFS 564/564A KFS 521A MLS KDM 706/706A KDF 806 KAA 455 KTU 709 System GOLD CROWN AVIONICS KPI 553B System GOLD CROWN AVIONICS KPI 553A System GOLD CROWN AVIONICS KPI 552B System GOLD CROWN AVIONICS KNI 582 System GOLD CROWN AVIONICS KNI 416 System GOLD CROWN AVIONICS KNI 415 System GOLD CROWN AVIONICS KMR 675 System GOLD CROWN AVIONICS KFS 598A System GOLD CROWN AVIONICS KFS 598 System GOLD CROWN AVIONICS KFS 594 System GOLD CROWN AVIONICS KFS 586A System GOLD CROWN AVIONICS KFS 586 System GOLD CROWN AVIONICS KFS 579A System GOLD CROWN AVIONICS KFS 576A System GOLD CROWN AVIONICS KFS 576 System GOLD CROWN AVIONICS KFS 564A System GOLD CROWN AVIONICS KFS 564 System GOLD CROWN AVIONICS KDM 706A System GOLD CROWN AVIONICS KDM 706 System GOLD CROWN AVIONICS KDI 574 System GOLD CROWN AVIONICS KDI 573 System GOLD CROWN AVIONICS KDI 572 System GOLD CROWN AVIONICS KCU 951 System GOLD CROWN AVIONICS KA 35 System GOLD CROWN AVIONICS