beautypg.com

Beckett 61687 GeniSys Display and Contractor Tool User Manual

Page 7

background image

7

GeniSys Display & Contractor Tool Installation and Operation Manual

To return to the CYCLE HISTORY
screen, press BACK (NO) once. To
return to the BURNER HISTORY
screen, press BACK (NO) a second
time.

C. Pre-time Set Program

From either the VIEW HISTORY
or the BURNER STATUS screens,
press and hold the NEXT key for 3
seconds. The Pre-time screen will
be displayed showing the current
Pre-time (valve-on delay) time setting.





NEXT

Hold for

3

seconds

To change the Pre-time setting, press
the SEL (YES) key. If the current
setting is zero a screen appears that
asks if a valve has been installed.
By pressing the BACK (NO) key, a
screen will be displayed as a reminder
that a valve is needed. See manual
supplied with burner. A valve must
be installed to operate in pre-time.

SEL

(YES)





If the response is SEL (YES), a select
Pre-time screen will be displayed. Use
the PREV and NEXT keys to select
the desired time setting. Pre-time can
be set to either 0, 5, 10, 15, 30, or
45 seconds. Note that if you install
a control that is programmed for

9.

1.

2.

3.

pre-time and/or post-time and the
burner does not have a valve, an
error will be detected by the control.

PREV

NEXT





After selecting the desired time,
press the SEL (YES) key to
display a confi rmation screen.

SEL

(YES)





To accept the change press SEL, to
return to the initial Pre-time screen
press the BACK(NO) key.

A BACK (NO) response will display a
CHANGE CANCELLED screen and
will return to the initial PRE-TIME
SELECT TO CHANGE
screen. A SEL
(YES)
response will update the pre-
time, then display the new time setting
on the initial PRE-TIME, SELECT TO
CHANGE
screen.

From the PRE-TIME, SELECT TO
CHANGE
screen, press PREV to
return to the VIEW HISTORY screen
(Paragraph B) or press NEXT to set
the Post-time (motor-off delay). Note
that replacement labels are supplied
in the packaging with the Display. After
changing the Pre and/or Post-time,
peel and mount the correct label over
the existing label being careful not to
cover the bar code.

4.

5.

6.

7.