Kn-cob-dp-ls operating characteristics – Kidde KN-COB-DP-LS User Manual
Page 13

6. KN-COB-DP-LS Operating Characteristics
Carbon
monoxide
alarm
Red LED flashes with
beeps.
4 quick beeps,
5 seconds silence,
repeating
Alarm condition.
Dangerous
concentrations of CO
detected
Refer to “What to do
When the Alarm Sounds”
(inside front cover)
Low
battery
Red LED flashes every
15 seconds
One quick beep
every 15 seconds
AC powered and low
or missing battery
Install or replace 9V bat-
tery.
Error/ serv-
ice alarm
Red LED flashes every
30 seconds
One quick beep
every 30 seconds
Unit is in error condition
Error
Red LED
constantly on
Constant alarm
Very low battery or unit
malfunction
Replace battery.
If “Err” continues, unit
has malfunctioned.
Replace immediately. Unit
will not respond CO
Normal
Test/Reset
function
Red LED flashes with
beeps. Green LED is
on.
4 quick beeps,
5 seconds silence,
repeated once
Normal operation when
Test/Reset button is
pressed
CO not detected. Alarm
for test purposes only
Operating and Alarm Characteristics
Function
LED Display
Alarm Sound
Unit Status
Recommendation
Normal
Operation
Green LED
constantly on
None
Normal AC
operation (sensing no
CO) and with a good
battery
None
Normal
Operation
Green LED flashes
every 10 seconds
None
Normal DC operation
on 9V battery backup
Verify AC power is
restored as soon as
possible to conserve
battery. Replace battery.
Within a few minutes, your carbon monoxide alarm will start monitoring for
CO and will continue to do so as long as it receives power.
When the Model KN-COB-DP-LS CO alarm loses power: If you have a good
9V battery installed, the alarm will automatically switch to the battery back-
up mode and the green LED will flash approximately every 10 seconds. The
unit will continue to operate normally and detect CO for at least 20 hours.
If the battery is low or missing, or if the unit malfunctions, it will alarm dif-
ferently to alert you of specific conditions. Please familiarize yourself, and
other family members, of the difference between a CO alarm and an indica-
tion signifying a problem with the unit.
When AC power is restored, the alarm will automatically switch back to nor-
mal operating mode and the green LED will come on continuously. Observe
the CO alarm regularly to make sure the green Operate LED is on, indicating
normal operation. If the green Operate LED is not on, unplug the CO alarm,
then plug it in again. This will clear the alarm for restart. If the green oper-
ate LED does not light, your CO alarm may be malfunctioning.
The following table describes the audible alarm patterns and the recom-
mended actions to take.
End of
unit life
indicator
Red LED flashes
every 30 seconds
Unit beeps 2
times every 30
seconds
End of unit life
Replace unit immediately.