6. KN-COB-DP-LS Operating Characteristics

Carbon
monoxide
alarm

Red LED flashes with
beeps.

4 quick beeps,
5 seconds silence,
repeating

Alarm condition.
Dangerous
concentrations of CO
detected

Refer to “What to do
When the Alarm Sounds”
(inside front cover)

Low
battery

Red LED flashes every
15 seconds

One quick beep
every 15 seconds

AC powered and low
or missing battery

Install or replace 9V bat-
tery.

Error/ serv-
ice alarm

Red LED flashes every
30 seconds

One quick beep
every 30 seconds

Unit is in error condition

Error

Red LED
constantly on

Constant alarm

Very low battery or unit
malfunction

Replace battery.
If “Err” continues, unit
has malfunctioned.
Replace immediately. Unit
will not respond CO

Normal
Test/Reset
function

Red LED flashes with
beeps. Green LED is
on.

4 quick beeps,
5 seconds silence,
repeated once

Normal operation when
Test/Reset button is
pressed

CO not detected. Alarm
for test purposes only

Operating and Alarm Characteristics

Function

LED Display

Alarm Sound

Unit Status

Recommendation

Normal
Operation

Green LED
constantly on

None

Normal AC
operation (sensing no
CO) and with a good
battery

None

Normal
Operation

Green LED flashes
every 10 seconds

None

Normal DC operation
on 9V battery backup

Verify AC power is
restored as soon as
possible to conserve
battery. Replace battery.

Within a few minutes, your carbon monoxide alarm will start monitoring for
CO and will continue to do so as long as it receives power.

When the Model KN-COB-DP-LS CO alarm loses power: If you have a good
9V battery installed, the alarm will automatically switch to the battery back-
up mode and the green LED will flash approximately every 10 seconds. The
unit will continue to operate normally and detect CO for at least 20 hours.

If the battery is low or missing, or if the unit malfunctions, it will alarm dif-
ferently to alert you of specific conditions. Please familiarize yourself, and
other family members, of the difference between a CO alarm and an indica-
tion signifying a problem with the unit.

When AC power is restored, the alarm will automatically switch back to nor-
mal operating mode and the green LED will come on continuously. Observe
the CO alarm regularly to make sure the green Operate LED is on, indicating
normal operation. If the green Operate LED is not on, unplug the CO alarm,
then plug it in again. This will clear the alarm for restart. If the green oper-
ate LED does not light, your CO alarm may be malfunctioning.

The following table describes the audible alarm patterns and the recom-
mended actions to take.

End of
unit life
indicator

Red LED flashes
every 30 seconds

Unit beeps 2
times every 30
seconds

End of unit life

Replace unit immediately.
Unit will not
respond to CO

2526-7206-00(820-1371 Rev. C).qxd:_ 2012.11.5 2:22 PM