2. Product Features and Specifications
battery to be changed without the alarm sounding. To deactivate the
feature, press in the Tamper-Resist Activation switch and move the
disable slide towards the switch.
WARNING: Failing to remove the battery prior to activating the
tamper resist feature will result in the unit going into an IMMEDIATE
constant audible tone condition if the unit has been powered for
2 minutes or longer. As the alarm sounds at 85 dB having the alarm in
extremely close proximity to your ears at time of activation could
potentially result in injury.
Low Battery Warning
If the 9V battery is missing or battery power is low, the unit will chirp
every 15 seconds to indicate the battery must be replaced. If the battery
is depleted beyond the point of having the capacity to operate the unit,
it will chirp every 30 to 45 seconds and will NOT respond to the test
button being pressed if operating on battery power.THE BATTERY
MUST BE REPLACED IMMEDIATELY!
Low Battery HUSH
®
CONTROL
When the battery needs to be replaced, the unit will produce a low
battery warning. The Low Battery HUSH® feature allows you to press
the button on the alarm and disable the “chirp” for a random period of
up to 12 hours. This gives you a chance to replace the battery at a more
convenient time. During this Low Battery HUSH® period, your alarm is
monitoring for CO.
IMPORTANT: Ten (10) years after the initial power up, this alarm
will “beep” every 30 seconds to indicate that it is time to replace
the alarm. Replace the alarm immediately! It will not detect CO in
this condition.
To help identify the date to replace the alarm, a label has been affixed to
the side of the alarm. Write the “replace by” date (ten years from power
up) in a permanent marker on this label.
Temperature:
Operating Range: 40°F (4.4°C) to 100°F (37.8°C)
Humidity:
Operating range: 10-95% non-condensing
Audible Alarm:
85+ dB at 10’ @ 3.4±0.5 KHz pulsing alarm
Sensor:
Electrochemical
Power:
120 volts AC, 60 Hz, 60 mA max, 9 volt battery back-up
Alarm Response Times:
70 PPM = 60-240 min., 150 PPM = 10-50 min., 400 PPM = 4-15 min.
!