beautypg.com

Rane SSE 22 User Manual

Page 6

background image

Manual-6

All features & specifications subject to change without notice. AUG97

©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5098 TEL (425)355-6000 FAX (425)347-7757 WEB http://www.rane.com

SSE 22 FEATURES AND SPECIFICATIONS

Parameter

Specification

Limit

Units

Conditions/Comments

Graphic Equalizer Sections:

Left & Right

..........Bands

(11) 1/3-Octave ISO Spacing

From 80 Hz to 800 Hz

..........Type

Interpolating Constant-Q

Smooth Combining

..........Travel

20

mm

Positive Grounded Center Detent

..........Range

±6

0.25

dB

Parametric Equalizer Sections:

Left & Right

..........Frequency Range

1 kHz-10 kHz

..........Bandwidth Range

0.7-3.5 octaves (Q=2.0-0.33)

..........Amplitude Range

±6

0.25

dB

Inputs: Type

Active Unbalanced

RCA Phono Connectors

..........Impedance

10k

1%

ohms

..........Maximum Level

34.5

1

dBr

11 Volts peak

Outputs: Type

Active Unbalanced

RCA Phono Connectors

..........Impedance

50

1%

ohms

..........Maximum Level

+34.5 > = 2k ohm

1

dBr

11 Volts peak

Frequency Response

20 Hz-20 kHz

+0/-.2

dB

Group Delay

Linear (Minimum Phase)

±5°

20-20 kHz

THD+Noise

0.001

.0005

%

1 kHz, +27.5 dBr (5 V peak)

Signal-to-Noise

120

1

dB

re 5 V pk; A-wtg; input short; flat

-92.5

1

dBr

A-wtg; input short, flat

-90.5

1

dBr

20 kHz BW; input short, flat

-84.5

1

dBr

A-wtg; input short, full boost

-87.5

1

dBr

A-wtg; input short, full cut

Dynamic Range

127

1

dB

Max out/noise floor (+34.5dBr/-92.5dBr)

Channel Separation

90

min

dB

20-20 kHz

Unit: Agency Listing
..........120 VAC model

Class 2 Equipment

National Electrical Code

UL 813 Exempt

Class 2

CSA Exempt

Class 2

..........230 VAC model

VDE, SELV

Safety Extra Low Voltage

CE-EMC

EMC directive 89/336/EEC

CE-Safety Exempt

Article 1 of LV Directive 73/23/EEC

Power Supply: Agency Listing

Class 2 Equipment

..........120 VAC model

UL listed

File no. E88261

CSA Certified

File no. LR58948

..........230 VAC model

CE-EMC

Meets EMC Directive 89/336/EEC

CE-Safety

LV Directive 73/23/EEC

Power Supply: Input

18 VAC w/center tap

10%

Vrms

Model RS 1

..........Current

750

max

mA

RMS Current From Remote Supply

Unit: Size

1.75"H x 19"W x 8.5"D (2U)

(4.4 cm x 48.3 cm x 21.6 cm)

17 3/8" wide w/o rack ears

(44.2 cm wide without rack ears)

..........Weight

5 lb

(2.3 kg)

Shipping: Size

4.25" x 20.3" x 13.75"

(11 cm x 52 cm x 35 cm)

..........Weight

8 lb

(3.6 kg)

Note: 0 dBr=150 mVrms=Home THX Equalizer Reference Level