MRP and RIP Connections

When wiring to Euroblocks, a minimum wire gauge of 22

is preferred for reliability. If the ground or shield wire is left

shorter, it acts as a strain relief for the other wires. Cable with

a flexible jacket is easier to use and less likely to damage the

connections. Avoid stripping excess insulation. Inspect wires for

nicks that may lead to wire breakage. Fully insert each wire in

the appropriate socket and tighten the screw. Turn the power to

the unit off until all connections are made.

Wire Types

Variations in wire type do not greatly affect the performance

of the remote controls. However, 22-gauge stranded wire with

a flexible jacket is recommended. You may use 5- conductor

unshielded remote control signal cable for shorter runs (less than

200 ft.) or 4-conductor (2 pair) shielded remote control signal

cable (use the shield as the GND return) for longer runs (200 to

1000 ft.). The type of wire required is influenced by your instal-

lation and local electrical codes. Rane Corporation does not pro-

vide or source cable. Please contact your local retail or wholesale

outlet, not the factory.

The following is a short list of suitable cable types:

CONSOLIDATED ELECTRONIC WIRE AND CABLE

Plenum cable:

Unshielded remote control signal cable CAT. #9896

Shielded remote control signal cable CAT. #9877 or #9852

WEICO WIRE & CABLE INC.

Communication and control cable:

Multiconductor, unshielded CAT. #7606

ALPHA

Communication and control cable:

Multiconductor, unshielded CAT. #1175C

BELDEN

Unshielded remote control signal cable CAT. #88741

Shielded remote control signal cable CAT. #88723

1

2

3

4

5

6

7

8

Mode

Result

1

0

0

0

0

0

0

0

1

0

1

0

0

0

0

0

0

2

0

0

1

0

0

0

0

0

3

0

0

0

1

0

0

0

0

4

0

0

0

0

1

0

0

0

5

0

0

0

0

0

1

0

0

6

0

0

0

0

0

0

1

0

7

0

0

0

0

0

0

0

1

8

0

0

0

0

0

1

1

1

1

1

0

0

0

0

1

1

1

2

0

1

0

0

0

1

1

1

3

1

1

0

0

0

1

1

1

4

0

0

1

0

0

1

1

1

5

1

0

1

0

0

1

1

1

6

0

0

0

1

0

1

1

1

7

1

0

0

1

0

1

1

1

8

0

0

0

0

1

1

1

1

9

1

0

0

0

1

1

1

1

10

0

0

0

0

0

1

0

1

no change

1

0

0

0

0

1

0

1

1

0

1

0

0

0

1

0

1

2

1

1

0

0

0

1

0

1

3

0

0

1

0

0

1

0

1

4

1

0

1

0

0

1

0

1

5

0

1

1

0

0

1

0

1

6

1

1

1

0

0

1

0

1

7

0

0

0

1

0

1

0

1

8

1

0

0

1

0

1

0

1

9

0

1

0

1

0

1

0

1

10

1

1

0

1

0

1

0

1

11

0

0

1

1

0

1

0

1

12

1

0

1

1

0

1

0

1

13

0

1

1

1

0

1

0

1

14

1

1

1

1

0

1

0

1

15

0

0

0

0

1

1

0

1

16

1

0

0

0

1

1

0

1

17

0

1

0

0

1

1

0

1

18

1

1

0

0

1

1

0

1

19

0

0

1

0

1

1

0

1

20

1

0

1

0

1

1

0

1

21

0

1

1

0

1

1

0

1

22

1

1

1

0

1

1

0

1

23

0

0

0

1

1

1

0

1

24

Table 1. MRP Binary Control

Paging

Binary

Normal