Rane ECM 64 User Manual
Page 22

Manual-22
STATUS consist of 20 bytes returned in this order:
Byte
Parameter
Value
1
OPSTAT
See OPSTAT
2
Preset Memory
1 - 16
3
Working/Stored Flag
1/0 (See Note 6)
4
Working/Dirty Flag
1/0 (See Note 7)
5
Meter Display
0 - 7, 0 = Mic Mix, 1 = Line In, 2 = Aux in, 3 = Hybrid Rx, 4 = Out 1, 5 = Out 2, 6 = Out 3,
7 = Hybrid Tx.
6
Meter Level
-45 to +9 dB
7
Off Hook Flag
1/0, 1 = Off Hook
8
New Ring Flag
1/0, 1= Ring detected - Cleared when read
9
Privacy Flag
1/0, 1 = Privacy On
10
Mute Flag
1/0, 1 = Mute On
11
Suppression Flag
1/0, 1 = Suppression active
12
AEC Installed
Firmware Rev or 0 if not installed
13
Hybrid Installed
Firmware Rev or 0 if not installed
14
DTMF Number
(Char) Set to 0 after read.
15
Prog. Out Level
0 - 118 Value for SPL 34
16 - 20 Reserved
0, Not used
Flash COM LEDs on all units (00 hex):
Transmit $FB 00 $FB 00
Transmit $00 $02 (where $02 = number of data bytes to follow including checksum)
Transmit $00 (command code)
Transmit $FE (checksum)
Get Data From Channel (01 hex):
Transmit ADDR header ($FB XX $FB XX, where XX = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $08 (where $08 = number of data bytes to follow including checksum)
Transmit $01 (command code)
Transmit $00 (CHNUM)
Transmit MEMNUM
Transmit 2 bytes; the starting SPL param byte index (See Note 5)
Transmit 2 bytes; the number of SPL param bytes (See Note 5)
Transmit Checksum
Get COMSTAT
Get Device Type and Manufacture’s Identification Codes (02 hex):
Transmit ADDR header ($FB XX $FB XX, where XX = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $02 (where $02 = number of data bytes to follow including checksum)
Transmit $02 (command code)
Transmit $FC (checksum)
Get COMSTAT
Get Globals (03 hex):
Transmit ADDR header ($FB XX $FB XX, where XX = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $02 (where $02 = number of data bytes to follow including checksum)
Transmit $03 (command code)
Transmit $FB $FB (checksum, See Note 1)
Get Global Parameters
Get Checksum
Get COMSTAT