Send Globals (8C hex):
Transmit ADDR header ($FB XX $FB XX, where XX = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $72 (where $72 = number of data bytes to follow including checksum)
Transmit $8C (command code)
Transmit Global Parameters
Transmit Checksum
Get COMSTAT

Global Parameters (114 bytes):
Type

Bytes

Description

Unit Name

16

ASCII string

Input Names

56

ASCII string (Mics 1-4, Line, Aux, Hybrid)

Output Names

32

ASCII string (Out 1-3, Hybrid)

Font Panel

1

1 if front panel switches are disabled

Locked

1

1 if unit is locked (read-only)

Elapsed Time

4

Time of use in seconds (read-only)

Reserved

4

Stored Number Parameter List SNPL (120 bytes):
Encoding Method: Null terminated ASCII string, or 20 characters max.
Index

Hex

Parameters

00-19

$00-$13 DTMF Number 1

20-39

$14-$27 DTMF Number 2

40-59

$28-$3BDTMF Number 3

60-79

$3C-$4FDTMF Number 4

80-99

$50-$63 DTMF Number 5

100-119 $64-$77 DTMF Number 6
A ‘,’ within the DTMF number inserts a 500 millisecond delay.
A non-digit within the DTMF number is allowed for separation (425.355.6000).

Send Stored DTMF Numbers ($8D)
Transmit ADDR header ($FB XX $FB XX, where XX = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $X2 (where $X2 = number of data bytes to follow including checksum)
Transmit $8D (command code)
Transmit the starting SNPL index (0 = Beginning of the first SNPL)
Transmit SNPL
Transmit Checksum
Get COMSTAT

Reset Unit (91 hex):
Transmit ADDR header ($FB XX $FB XX, where XX = ADDR) (See Note 9)
Get DT
Get ID
Transmit $00 $03 (where $03 = number of data bytes to follow including checksum)
Transmit $91 (command code)
Transmit RESET ($00 = Reset unit, $01 = Reset unit and set all data to default. Warning: If Firmware has been downloaded,
program returns to original version.)
Transmit Checksum
Get COMSTAT