OPERATING INSTRUCTIONS

A PRIMER
Let’s start with what a compressor actually does. No matter how

you cut it, this is an automatic volume control. It is a hand on

a knob, turning the volume down and turning it up again. The

hand is really quick and really accurate, but it’s just turning a

volume control.

When the input signal reaches a level set by the COMPRES-

SOR THRESHOLD control, the compressor begins turning

down the signal by an amount determined by the RATIO

control. The DC 22S, like most compressors, operates by mak-

ing the loud signals quieter, but does not make the quiet parts

louder. However, by keeping the loud signals under control, the

entire system may be turned up when necessary to make the

quiet parts louder.

PRE-FLIGHT CHECKLIST
Before proceeding, it’s a good idea to turn the control knobs to

the following positions:

1. GATE THRESHOLD control .....fully counterclockwise

2. COMPRESSOR THRESHOLD ...fully clockwise

3. COMPRESSOR RATIO ..............fully counterclockwise

4. BYPASS switches .....................ACTIVE (out)

5. OUTPUT LEVEL ........................0 dB

This renders the DC 22S with no compression, allowing sig-

nal through at unity gain. No change occurs with the BYPASS

switch in or out.

INPUT LEVEL
Before making any Threshold adjustments, set the ouput level of

the previous device so the +4 dBu LED lights occasionally, and

the OL LED does not light. Be aware that changes to the Input

Level will affect the Thresholds.

GATE THRESHOLD
The threshold is the point at which gain adjustment begins. When

the input signal is below the threshold, the DC 22S attenuates

the signal at a 2:1 ratio, making the quiet parts twice as quiet.

When the signal is above the Gate Threshold, the Gate is open,

like a straight wire.

COMPRESSOR THRESHOLD
The threshold is the point at which gain adjustment begins. When

the input signal is below the threshold, the Compressor section

acts like a straight wire. When the signal is loud enough to cross

the Compressor Threshold, the compressor is active and turns

the volume down. Various Threshold points are illustrated in

Figure 1. How much it gets turned down is determined by the

RATIO control ( Figure 1 shows a Ratio set at 2:1).

RATIO

Figure 1. With a fixed Ratio set to 2:1, this graph shows gain reduction

below various Gate Thresholds at -20 dBu, -30 dBu, -40 dBu, etc.

FIgure 3. Threshold at -40 dBu. Ratios of 1:1, 1.2:1, 1.5:1, etc.

Vertical axis = output level, horizontal axis = input level.

AUDIO PRECISION amp

09 AUG 101 14:51:28

-80

-70

-60

-50

-40

-30

-20

-10

0

AMPL(dBr) vs AMPL(dBu)

-80

-70

-60

-50

-40

-30

-20

-10

0

INPUT (dBu)

O

U

T

P

U

T

d

B

u

Once the Threshold is exceeded, the increase in output compared

to the input signal increase depends on the RATIO setting. An

ordinary preamp set for unity gain or a straight wire has a ratio

of 1:1, that is, the output level tracks the input level perfectly. A 2

dB change at the input produces a 2 dB change at the output.

For a 10:1 Ratio, a 10 dB blast at the input would rise only

1 dB at the output – heavy compression. Kinder, gentler ratios

are in the 2:1 to 3:1 range. Limiting, with no increase in signal

above the Threshold, occurs at ∞:1. Figure 3 illustrates various

Ratios.

AUDIO PRECISION

09 AUG 101 14:34:57

-60

-50

-40

-30

-20

-10

0

10

20

-40

-30

-20

-10

0

10

AMPL(dBr) VS AMPL(dBu)

-60

-50

-40

-30

-20

-10

0

10

20

INPUT (dBu)

O

U

T

P

U

T

d

B

u

Figure 2. With the Ratio set to ∞, the DC 22S acts as a Limiter. This

graph shows Limiter gain reduction above various Compressor

Thresholds at 10 dBu, 0 dBu, -10 dBu, etc.

AUDIO PRECISION

09 AUG 101 14:45:47

-60

-50

-40

-30

-20

-10

0

10

20

AMPL(dBr) vs AMPL(dBu)

-60

-50

-40

-30

-20

-10

0

10

20

1:1

1.2:1

1.5:1

2:1

3:1

6:1

∞:1

INPUT (dBu)

O

U

T

P

U

T

d

B

u