12-2-15. Page Length Set Command
1
st
byte
D8
D1
0
0
0
1
1
0
1
1
ESC (1B) H
2
nd
byte
D8
D1
0
1
0
0
0
0
1
1
C(43)H
3
rd
byte
D8
D1
0
N7
N6
N5
N4
N3
N2
N1
n (Binary digits)
The length of one page is set to “n” lines by this command. (1
£n£127)
12-2-16. From Feed Command
1
st
byte
D8
D1
0
0
0
1
1
0
1
1
ESC (1B) H
2
nd
byte
D8
D1
0
1
1
0
0
1
1
0
f(66)H
3
rd
byte
D8
D1
0
0
0
0
0
0
0
0
1(01)H
The input of this command feeds the paper to the top of the next page, after printing the data
contained in the print buffer.
12-2-17. Skip Perforation Command
1
st
byte
D8
D1
0
0
0
1
1
0
1
1
ESC (1B) H
2
nd
byte
D8
D1
0
1
0
0
1
1
1
0
N(4E)H
3
rd
byte
D8
D1
0
N7
N6
N5
N4
N3
N2
N1
n (Binary digits)