8-3. Description of Input / Output Signals
8-3-1. Input / Output Signals
a)
Input / Output Signals
*DATA
: 8 bit parallel signal. (Positive logic)
*STB
: A strobe signal for reading in 8 bit data. (Negative logic)
*RESET
: A signal which resets the entire printer. (Negative logic, 1 ms or more)
b)
Output Signals (From Printer)
*ACK
: This is a pulse signal for requesting 8 bit data, issued at the end of a BUSY
signal. (Negative logic)
*BUSY
: This signal indicates that your printer is in a BUSY state.
New data should be input when this signal is “LOU”. (Positive logic)
*FAULT
: When your printer is in an alarm state, this signal is “LOW”. At this time,
all control circuits of your printer are interrupted. (Negative logic)
Note: An alarm condition occurs when the timing of the print head movement sensor is abnormal.
c)
Power Source
*”H” Level
: H level out put for TTL level
*GND : The common circuit ground.
*FRAME GND
: Connect the shield of interface cable to this.