Citizen Systems iDP-3540 User Manual
Page 36
iDP-3540/41 User’s Manual
CITIZEN
36/48
12-2-8. Initial Set Command
D8
D1
0
0
0
1
0
0
0
1
DC1(11)H
The controller is initialized by this command and the following conditions are established.
*Internal input buffer cleared
* Normal character mode selected
* Black color print mode selected
* Skip designation cancelled
* Page length set to 66 lines
* Line feed pitch set to 2/9 inch (graphic type only)
12-2-9. Inverted character command
D8
D1
0
0
0
1
0
0
1
0
DC2(12)H
This command specifies inverted characters. By entering this command at the beginning of print
data and then sending the data to the controller, all of the following characters will be printed
upside down. This command remains valid until, either it is entered again or the initial set
command is entered.
12-2-10. Buzzer Command
D8
D1
0
0
0
0
0
1
1
1
RS(1E)H
Command to activate the alarm buzzer for 0.3 second period.