beautypg.com

Vermont castings ewf30, Common materials and factors, Example for common brick – Vermont Casting EWF30 User Manual

Page 16

background image

16

Vermont Castings EWF30

20008662

The top of insulation must be covered with a non-com-
bustible decorative covering or a piece of .018” mini-
mum sheet metal, to protect hearth extension material.
(Fig. 25)
Secure the hearth extension to the floor to prevent
shifting, using trim molding or other similar means at
three (3) outer edges. Seal crack between the fireplace
hearth and hearth extension with a noncombustible
material. (Figs. 24 and 25)
WARNING: Hearth extension must be installed in
accordance with Figure 24. Top of hearth extension
must be level with bottom of fireplace.
Alternate noncombustible materials may be used
providing the (total) thermal resistance (Rt value) of the
alternate material employed is greater than or equal to
R = 1.09 Thermal resistance (R) or thermal conductivity
(K), may be obtained from manufacturer of the material.
Factors are related by the formula K = 1/R. (Fig. 23)
T = given thickness
R = thermal resistance for a given thickness (T)
K = thermal conductivity
Noncombustible material with a lower R value may
be used, provided thickness of material is sufficiently
greater to maintain an equivalent (total) thermal resis-
tance (Rt).

Example of Determining Hearth Extension

Equivalents

To determine the thickness required for any new mate-
rial:

Example for Common Brick

T (new) = 5.0/0.458 x 0.50 in. = 5.46 in. (new required
thickness).

FP1202a

EWF30

SEALING DETAILS

6/05

Wall Covering

2 x 4 Header - Do not

notch at standoffs

Noncombustible

Decorative

Facing

Seal all cracks

between fireplace sur-

round (steel) and wall

materials with noncom-

bustible material.

Cast Front

Noncombustible

Decorative

Covering

Safety Strips - Must be

overlapped 1/2” minimum

FP1202a

Fig. 24 Sealing gaps.

NOTE: No

material

may cover

black cast

face.

COMMON MATERIALS AND FACTORS

MATERIAL

K*

R

MINIMUM

THICKNESS

EH2416

Common Brick

0.916

5.0

2.18 1.0 in.**

0.10 5.46 in.**

(CFM Corporation)

R Value is for 1/2 inch.

* Units of K = BTU/SQ FT/HR/˚F/IN

** Thickness of Listed Material

FP533ADD

Addendum

6/1/99 djt

8/4/99 changed .2 to .1

one inch to 1/2 inch djt

FP533ADD

Fig. 23 Hearth extension material factors.

NEW

K of new material (per inch)

thickness

required

=

X of listed

thickness

K of listed material (per inch)

material

Noncombustible

Material