Optional features and accessories – Pilgrim Pressure Switches B-SERIES User Manual
Page 10
10
OPTIONAL FEATURES AND ACCESSORIES
ATEX Directive 94/9/EC APPROVAL
FOR HAZARDOUS LOCATIONS
ATEX is a European designation that
deals with standards for equipment and
protective systems intended for use in
potentially explosive atmospheres. This
approval is required for switches intended
for use in hazardous locations, especially
important to OEMs who export to Europe
and contractors specifying or purchasing
products for European applications.
XCN option adds special features to
Ashcroft 700-Series switch enclosures
that meet the requirements for the highest
levels of security and danger,
such as:
• Special locking device requiring an Allen
wrench to remove cover
• Special vents that blow out should the
diaphragm rupture, thus preventing
pressure build-up in the enclosure
• Special conduit plug requiring an Allen
wrench for removal
• Available on pressure, temperature and
differential pressure models
• Meets Explosion Class EEx d IIC T6
Order option XCN
14 Available in ranges vacuum to 600 psi. Not
available with stainless steel or Monel
diaphragm.
15 Buna N and Viton diaphragm – 15#D &
30#D only.
16 24, 32, 64 or 68 element only.
17 N/A on all combinations
8 Pressure connection
1
⁄
4
NPTF.
9 Standard on 700 Series. N/A with DPDT
element on 400 Series.
10 N/A with Monel diaphragm.
11 Standard on 400 Series.
12 N/A on 3000 psi range. Available with Teflon
diaphragm only.
13 SS diaphragm required. Teflon diaphragm is the
backup. NEMA 7 only.
B-SERIES SWITCH OPTIONS
Appicable Switch Series
Differential
Temp-
Pressure
Pressure
erature
H
All
Code
Description
(psi)
(in. H
2
O)
(psi)
(in. H
2
O) Ranges
Notes
XBP Wall Mounting Bracket in. H
2
O
•
•
XBX
1
⁄
2
˝ Male NPT Bushing
•
XCH Chained Cover
•
•
•
•
•
•
XC8 CSA Approval
•
•
•
•
•
11
XCN ATEX Directive 94/9/EC EEx d IIC T6
•
•
•
•
•
XFM FM Approval – Single Element
•
•
•
•
17
FM Approval – Dual Element
•
•
•
•
17
XFP Fungus Proofing
•
•
•
•
•
•
XFS Factory Adjusted Setpoint
•
•
•
•
•
•
2
XG3 Belleville Actuator
•
16,17
XG4 Teflon Actuator and Pressure Conn.
•
8
XG5 UL Limit Control to 150˝ H
2
O
•
1, 17
XG6 UL Limit Control to 600 psi
•
1, 17
XG7 Secondary Chamber with Vent
•
13
XG8 Steam Limit Control to 300 psi
•
7
XG9 Fire Safe Welded Actuator
•
7
XHS High Static Diflerential Pressure
•
15
High Pressure, 40 psi, (static) DIP
XHX 160 psi (proof) DIP
•
•
100 psi proof pressure
XJK Left Conduit Connection
•
•
•
•
•
•
9
XJL
3
⁄
4
˝ to
1
⁄
2
˝ Reducing Bushing
•
•
•
•
•
•
XK3 Terminal Block (700 Series only)
•
•
•
•
•
6
XLE Long Leads on the Micro Switch
•
•
•
•
•
•
XL9
Low Hardness SS Press. Conn.
•
12
XNH Tagging Stainless Steel
•
•
•
•
•
•
XNN Paper Tag
•
•
•
•
•
•
XPK Pilot Light(s) Top Mounted
•
•
•
•
•
•
4
XPM
3
⁄
4
˝ Sealed Conduit Connection
with 16˝ Lead Wires
•
•
•
•
•
•
XTA 316 Stainless Steel Pressure
•
•
Connection for in. H
2
O Range
XTM 2˝ Pipe Mounting Bracket
•
•
•
•
•
XUD 316 Stainless Steel Pressure Conn.
•
Pressure Connection:
X06
1
⁄
2
NPT Male,
1
⁄
4
NPT Female
•
•
•
•
5
316 Stainless Steel (Combination)
X07
1
⁄
2
NPTF Press. Conn., 316 SS
•
•
•
•
10
X2B Breather Drain
•
•
•
•
•
X6B Cleaned for Oxygen Service
•
•
•
3
Diaphragm Seal
•
•
•
•
NOTES:
1 Buna N and Viton diaphragm.
2 Advise static or working pressure for differential
pressure switches.
3 Buna N cannot be cleaned for oxygen service.
4 N/A on 700 Series.
5 Standard with 1000 and 3000 psi ranges. Bottom
connection only on DP in H
2
O ranges.
6 Terminal Blocks standard with 700 dual switches.
7 Stainless steel diaphragm only.