Type 700 dimensions, 6 lb (1.6 kg) – Pilgrim Pressure Switches B-SERIES User Manual
Page 13
C
A
U
T
IO
N
TO
PR
EV
EN
T IGNITION OF
H
A
Z
A
R
D
O
U
S
AT
MO
SPH
ERE TURN
OF
F
P
O
W
E
R
B
E
FO
RE
OPENING. CLO
SE
T
IG
H
T
LY
BE
FO
RE OPERAT
IN
G
.
C
A
U
T
IO
N
C
O
UP
ER
LE
CO
UR
AN
TA
VA
N
T
D
’O
U
V
R
IR
.
B
IE
N
FE
RM
ER
AV
AN
T
DE
M
E
T
T
R
E
E
N
SE
RV
IC
E.
E
I
G
M
H
K
0.28 THRU
(3 PLACES)
1/4 NPT
FEMALE
3/4 NPT
(2 PLACES)
B
BRACKET WHEN
REQUIRED “XBP”
VARIATION
J
A
L
N
13
A
B
E
G
H
I
J
K
L
M
N
6
7
⁄
16
5
7
⁄
32
3
7
⁄
8
1
7
⁄
32
5
⁄
16
3
31
⁄
32
2
25
⁄
32
5
1
⁄
8
3
1
⁄
16
5
11
⁄
16
3
1
⁄
2
(164) (133)
(98)
(31)
(8)
(101)
(71)
(130)
(78)
(145)
(89)
C
A
U
T
IO
N
TO
PR
EV
EN
T IGNITION OF
H
A
Z
A
R
D
O
U
S
AT
MO
SPH
ERE TURN
OF
F
P
O
W
E
R
B
E
FO
RE
OPENING. CLO
SE
T
IG
H
T
LY
BE
FO
RE OPERAT
IN
G
.
C
A
U
T
IO
N
C
O
UP
ER
LE
CO
UR
AN
TA
VA
N
T
D
’O
U
V
R
IR
.
B
IE
N
FE
RM
ER
AV
AN
T
DE
M
E
T
T
R
E
E
N
SE
RV
IC
E.
B
3/4 NPT
(2 PLACES)
A
C
E
I
G
H
F
J
0.28 THRU
(3 PLACES)
P
See Order
Info Page
7/8 HEX
1/2 NPT
MALE
2.31 (59)
ACTIVE
BULB
LENGTH
Ø 3/8 (9mm)
D
C
A
U
T
IO
N
TO
PR
EV
EN
T IGNITION OF
H
A
Z
A
R
D
O
U
S
AT
MO
SPH
ERE TURN
OF
F
P
O
W
E
R
B
E
FO
RE
OPENING. CLO
SE
T
IG
H
T
LY
BE
FO
RE OPERAT
IN
G
.
C
A
U
T
IO
N
C
O
UP
ER
LE
CO
UR
AN
TA
VA
N
T
D
’O
U
V
R
IR
.
B
IE
N
FE
RM
ER
AV
AN
T
DE
M
E
T
T
R
E
E
N
SE
RV
IC
E.
B
3/4 NPT
(2 PLACES)
A
C
E
I
G
H
F
J
0.28 THRU
(3 PLACES)
2.31 (59)
ACTIVE
BULB
LENGTH
Q See Order
Info Page
Ø 3/8 (9mm)
R
D
A
B
C
D
E
F
G
H
I
J
P
5
3
⁄
32
5
7
⁄
32
4
3
⁄
8
3
5
⁄
8
3
7
⁄
8
2
5
⁄
16
1
7
⁄
32
5
⁄
16
3
31
⁄
32
1
15
⁄
16
1
5
⁄
16
(129) (133) (111) (92) (98) (59) (31)
(8) (101) (49) (33)
3.7 lb
(1.7 kg)
4.5 lb
(2.0 kg)
Temperature switch – direct mount
Temperature switch – remote mount
A
B
C
D
E
F
G
H
I
J
Q
R
5
3
⁄
32
5
7
⁄
32
4
3
⁄
8
3
5
⁄
8
3
7
⁄
8
2
5
⁄
16
1
7
⁄
32
5
⁄
16
3
31
⁄
32
1
15
⁄
16
3
3
(129) (133) (111) (92) (98) (59) (31)
(8) (101) (49) (76) (76)
C
A
U
T
IO
N
TO
PR
EV
EN
T IGNITION OF
H
A
Z
A
R
D
O
U
S
AT
MO
SPH
ERE TURN
OF
F
P
O
W
E
R
B
E
FO
RE
OPENING. CLO
SE
T
IG
H
T
LY
BE
FO
RE OPERAT
IN
G
.
C
A
U
T
IO
N
C
O
UP
ER
LE
CO
UR
AN
TA
VA
N
T
D
’O
U
V
R
IR
.
B
IE
N
FE
RM
ER
AV
AN
T
DE
M
E
T
T
R
E
E
N
SE
RV
IC
E.
A
B
C
I
G
H
F
J
0.28 THRU
(3 PLACES)
1/4 NPT
FEMALE
3/4 NPT
(2 PLACES)
E
D
A
B
C
D
E
F
G
H
I
J
5
3
⁄
4
5
7
⁄
32
4
3
⁄
8
3
5
⁄
8
3
7
⁄
8
2
5
⁄
16
1
7
⁄
32
5
⁄
16
3
31
⁄
32
1
15
⁄
16
(146) (133) (111)
(92)
(98)
(59)
(31)
(8)
(101)
(49)
C
A
U
T
IO
N
TO
PR
EV
EN
T IGNITION OF
H
A
Z
A
R
D
O
U
S
AT
MO
SPH
ERE TURN
OF
F
P
O
W
E
R
B
E
FO
RE
OPENING. CLO
SE
T
IG
H
T
LY
BE
FO
RE OPERAT
IN
G
.
C
A
U
T
IO
N
C
O
UP
ER
LE
CO
UR
AN
TA
VA
N
T
D
’O
U
V
R
IR
.
B
IE
N
FE
RM
ER
AV
AN
T
DE
M
E
T
T
R
E
E
N
SE
RV
IC
E.
B
A
C
H
I
G
F
0.28 THRU
(3 PLACES)
3/4 NPT
(2 PLACES)
1/4 NPT
LOW PRESSURE
INLET
1/4 NPT HIGH
PRESSURE
INLET
O
E
D
A
B
C
D
E
F
G
H
I
O
7
25
⁄
32
5
7
⁄
32
4
3
⁄
8
3
5
⁄
8
3
7
⁄
8
2
5
⁄
16
1
7
⁄
32
5
⁄
16
3
31
⁄
32
3
11
⁄
16
(198) (133) (111)
(92)
(98)
(59)
(31)
(8)
(101)
(94)
A
B
E
G
H
I
J
K
L
M
N
6
7
⁄
16
5
7
⁄
32
3
7
⁄
8
1
7
⁄
32
5
⁄
16
3
31
⁄
32
2
25
⁄
32
5
1
⁄
8
3
1
⁄
16
5
11
⁄
16
3
1
⁄
2
(164) (133)
(98)
(31)
(8)
(101)
(71)
(130)
(78)
(145)
(89)
2.7 lb
(1.2 kg)
4.5 lb
(2.0 kg)
3.6 lb
(1.6 kg)
Pressure switch – psi ranges
Pressure switch –
inches of water ranges
Differential pressure switch –
psi differential ranges
TYPE 700 DIMENSIONS
C
A
U
T
IO
N
TO
PR
EV
EN
T IGNITION OF
H
A
Z
A
R
D
O
U
S
AT
MO
SPH
ERE TURN
OF
F
P
O
W
E
R
B
E
FO
RE
OPENING. CLO
SE
T
IG
H
T
LY
BE
FO
RE OPERAT
IN
G
.
C
A
U
T
IO
N
C
O
UP
ER
LE
CO
UR
AN
TA
VA
N
T
D
’O
U
V
R
IR.
B
IE
N
FE
RM
ER
AV
AN
T
DE
M
E
T
T
R
E
E
N
SE
RV
IC
E.
E
I
G
M
H
K
0.28 THRU
(3 PLACES)
1/4 NPT
FEMALE
3/4 NPT
(2 PLACES)
B
BRACKET WHEN
REQUIRED “XBP”
VARIATION
J
A
1/4 NPT
FEMALE
(DP ONLY)
L
N
3.6 lb
(1.6 kg)
Differential pressure switch –
inches of water ranges