Type 1032 Sanitary Pressure Gauge

BULLETIN SG-2

FEATURES

• PLUS!

Performance is available on

2

1

2

,˝ 3

1

2

,˝ 4

1

2

˝ gauges for liquid filled

performance in a dry case gauge.

• All-welded 316L SS Bourdon tube
• Welded 316L SS diaphragm and seal

housing

• USP grade glycerin (99.5% pure,

system fill) standard

• 3A compliance to standard 74-03
• 300 SS electropolished case and ring
• Electropolished diaphragm & housing
• Dry and liquid filled gauge versions

(1)

• Weatherproof and hermetically

sealed versions

• External Easy Zero

adjust standard

on dry, liquid filled and PLUS!

3

1

2

˝

size

• Individual calibration certificates

provided on request

Ashcroft

®

Type 1032 sanitary pressure

gauges have specifically been designed to
meet the need for sanitary-type pressure
gauges in the pharmaceutical, bio-tech,
filtration and food and dairy markets. With a
quick-connect clamp and diaphragm surface
finish that is electropolished to 12-20RA
these instruments are also suitable for use
in breweries, wineries and citrus juice pro-
duction plants. Available in dial sizes from
2˝ thru 4

1

2

˝ and Tri-Clamp

®

type connections

of

3

4

˝ thru 2,˝ Ashcroft’s selection of sani-

tary pressure gauges is unsurpassed.

To meet the needs of the markets

served, all Ashcroft sanitary gauges, with
optional polysulfone window, can be auto-
claved or sterilized to temperatures of
300°F (149°C) and can be cleaned or
steamed in place. Ashcroft Type 1032 sani-
tary gauges with dial sizes of 2

1

2

˝ and 3

1

2

˝

are furnished standard with the patented
PowerFlex

movement. Since the PowerFlex

movement is suspended from the Bourdon
tube, it resists the effects of pulsation and
vibration, a primary cause for gauge failure.

HOW TO ORDER

(Typical Example)

25

1032

S

(L)

15

L

X

100#

Dial Size: 2˝ 2

1

2

,˝ 3

1

2

,˝ 4

1

2

˝

Type: 1032, 316L SS tube/socket

Diaphragm: 316L SS

Liquid-Filled Case (optional)

Process Connection:

3

4

˝ (75), 1

1

2

˝ (15), 2˝ (20) Tri-Clamp

®

Connection Location: lower (L), back (B)

Optional Features

Pressure Range: 100 psi

SPECIFICATIONS

Dial Size: 2,˝ 2

1

2

,˝ 3

1

2

,˝ 4

1

2

˝

Accuracy: 2˝: 3% upscale, up to 5% downscale

(2)

2

1

2

,˝ 3

1

2

,˝ 4

1

2

˝: 1.5% F.S. for pressure ranges

100 psi and above. 2.0% F.S. for vacuum
compound and ranges below 100 psi.

Case & Ring Material: 300 SS electropolished

Ring Type: 2˝: Stainless steel, friction fit

2

1

2

,˝ 3

1

2

,˝ 4

1

2

˝: Bayonet, removable

Bourdon Tube and Socket Material: 316L SS

Diaphragm Material & Surface Finish:
316 SS, 12 to 20 RA electropolished

Process Connection:

2˝ dial size:

3

4

˝ Tri-Clamp

2

1

2

,˝ 3

1

2

˝ dial size: 1

1

2

˝ or 2˝ Tri-Clamp

4

1

2

˝ dial size: 2˝ Tri-Clamp only

Connection Location: 2˝: Lower

2

1

2

,˝ 3

1

2

,˝4

1

2

˝: Lower or back

System Fill: USP food grade glycerin standard.

Other materials available

Window Material: 2˝: Glass

2

1

2

,˝ 3

1

2

˝: Polycarbonate

(3)

4

1

2

˝: Glass

Pointer: 2˝: Black-painted aluminum, non-adjustable

2

1

2

˝: Black-painted aluminum, adjustable

3

1

2

˝: Black-painted aluminum with ext. adjust

4

1

2

˝: Black-painted aluminum, adjustable

Dial: White with black markings

Movement: 2

,

˝ 2

1

2

,˝ 3

1

2

˝: 300 SS, 4

1

2

˝: 400 SS

Agency Approvals:
3A compliance to sanitary standard 74-03

Ranges: 2˝: 30# thru 600#, incl. vac/30 psi lowest

2

1

2

,˝ 3

1

2

,˝ 4

1

2

˝: 15# thru 1000#, including

compound & vacuum

Clean or Steam in Place: (CIP or SIP): Process
temperature limit of 280°F (138°C)

Autoclave or Sterilize: Ambient temp. limit of 300°F
(149°C) when supplied with polysulfone window
(3

1

2

˝ dry gauge only).

(1) 2˝ 1032 not available liquid filled and not available in ranges

below 30psi.

(2) Gasket material and clamp torque tightness may effect gauge

accuracy. We use a buna o-ring gasket and 25 inch pounds of

clamp force when calibrating. Other gaskets could effect accuracy.

(3) We recommend a polysulfone window for autoclave/ sterilization.

Specify the XPS variation. Available in 3

1

2

˝ dry gauge only.

Tri-Clamps are not included, Tri-Clamp

®

is a registered

trademark of Alfa Laval Inc.

Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA
Tel: 203-378-8281 • Fax: 203-385-0408
email: [email protected] • www.ashcroft .com

All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
© Ashcroft Inc. 2010 06/10

Actual

material certificates

and certificate of conformance

supplied as standard to

EN 10204:2004 3.1

ZERO ADJUST

VENT PLUG

HEAT NUMBER

TRACEABILITY