Pilgrim Type 1032 Sanitary Pressure Gauge User Manual
Type 1032 sanitary pressure gauge, Features • plus, Performance is available on 2
Type 1032 Sanitary Pressure Gauge
BULLETIN SG-2
FEATURES
• PLUS!
™
Performance is available on
2
1
⁄
2
,˝ 3
1
⁄
2
,˝ 4
1
⁄
2
˝ gauges for liquid filled
performance in a dry case gauge.
• All-welded 316L SS Bourdon tube
• Welded 316L SS diaphragm and seal
housing
• USP grade glycerin (99.5% pure,
system fill) standard
• 3A compliance to standard 74-03
• 300 SS electropolished case and ring
• Electropolished diaphragm & housing
• Dry and liquid filled gauge versions
(1)
• Weatherproof and hermetically
sealed versions
• External Easy Zero
™
adjust standard
on dry, liquid filled and PLUS!
™
3
1
⁄
2
˝
size
• Individual calibration certificates
provided on request
Ashcroft
®
Type 1032 sanitary pressure
gauges have specifically been designed to
meet the need for sanitary-type pressure
gauges in the pharmaceutical, bio-tech,
filtration and food and dairy markets. With a
quick-connect clamp and diaphragm surface
finish that is electropolished to 12-20RA
these instruments are also suitable for use
in breweries, wineries and citrus juice pro-
duction plants. Available in dial sizes from
2˝ thru 4
1
⁄
2
˝ and Tri-Clamp
®
type connections
of
3
⁄
4
˝ thru 2,˝ Ashcroft’s selection of sani-
tary pressure gauges is unsurpassed.
To meet the needs of the markets
served, all Ashcroft sanitary gauges, with
optional polysulfone window, can be auto-
claved or sterilized to temperatures of
300°F (149°C) and can be cleaned or
steamed in place. Ashcroft Type 1032 sani-
tary gauges with dial sizes of 2
1
⁄
2
˝ and 3
1
⁄
2
˝
are furnished standard with the patented
PowerFlex
™
movement. Since the PowerFlex
movement is suspended from the Bourdon
tube, it resists the effects of pulsation and
vibration, a primary cause for gauge failure.
HOW TO ORDER
(Typical Example)
25
1032
S
(L)
15
L
X
100#
Dial Size: 2˝ 2
1
⁄
2
,˝ 3
1
⁄
2
,˝ 4
1
⁄
2
˝
Type: 1032, 316L SS tube/socket
Diaphragm: 316L SS
Liquid-Filled Case (optional)
Process Connection:
3
⁄
4
˝ (75), 1
1
⁄
2
˝ (15), 2˝ (20) Tri-Clamp
®
Connection Location: lower (L), back (B)
Optional Features
Pressure Range: 100 psi
SPECIFICATIONS
Dial Size: 2,˝ 2
1
⁄
2
,˝ 3
1
⁄
2
,˝ 4
1
⁄
2
˝
Accuracy: 2˝: 3% upscale, up to 5% downscale
(2)
2
1
⁄
2
,˝ 3
1
⁄
2
,˝ 4
1
⁄
2
˝: 1.5% F.S. for pressure ranges
100 psi and above. 2.0% F.S. for vacuum
compound and ranges below 100 psi.
Case & Ring Material: 300 SS electropolished
Ring Type: 2˝: Stainless steel, friction fit
2
1
⁄
2
,˝ 3
1
⁄
2
,˝ 4
1
⁄
2
˝: Bayonet, removable
Bourdon Tube and Socket Material: 316L SS
Diaphragm Material & Surface Finish:
316 SS, 12 to 20 RA electropolished
Process Connection:
2˝ dial size:
3
⁄
4
˝ Tri-Clamp
2
1
⁄
2
,˝ 3
1
⁄
2
˝ dial size: 1
1
⁄
2
˝ or 2˝ Tri-Clamp
4
1
⁄
2
˝ dial size: 2˝ Tri-Clamp only
Connection Location: 2˝: Lower
2
1
⁄
2
,˝ 3
1
⁄
2
,˝4
1
⁄
2
˝: Lower or back
System Fill: USP food grade glycerin standard.
Other materials available
Window Material: 2˝: Glass
2
1
⁄
2
,˝ 3
1
⁄
2
˝: Polycarbonate
(3)
4
1
⁄
2
˝: Glass
Pointer: 2˝: Black-painted aluminum, non-adjustable
2
1
⁄
2
˝: Black-painted aluminum, adjustable
3
1
⁄
2
˝: Black-painted aluminum with ext. adjust
4
1
⁄
2
˝: Black-painted aluminum, adjustable
Dial: White with black markings
Movement: 2
,
˝ 2
1
⁄
2
,˝ 3
1
⁄
2
˝: 300 SS, 4
1
⁄
2
˝: 400 SS
Agency Approvals:
3A compliance to sanitary standard 74-03
Ranges: 2˝: 30# thru 600#, incl. vac/30 psi lowest
2
1
⁄
2
,˝ 3
1
⁄
2
,˝ 4
1
⁄
2
˝: 15# thru 1000#, including
compound & vacuum
Clean or Steam in Place: (CIP or SIP): Process
temperature limit of 280°F (138°C)
Autoclave or Sterilize: Ambient temp. limit of 300°F
(149°C) when supplied with polysulfone window
(3
1
⁄
2
˝ dry gauge only).
(1) 2˝ 1032 not available liquid filled and not available in ranges
below 30psi.
(2) Gasket material and clamp torque tightness may effect gauge
accuracy. We use a buna o-ring gasket and 25 inch pounds of
clamp force when calibrating. Other gaskets could effect accuracy.
(3) We recommend a polysulfone window for autoclave/ sterilization.
Specify the XPS variation. Available in 3
1
⁄
2
˝ dry gauge only.
Tri-Clamps are not included, Tri-Clamp
®
is a registered
trademark of Alfa Laval Inc.
Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA
Tel: 203-378-8281 • Fax: 203-385-0408
email: [email protected] • www.ashcroft .com
All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
© Ashcroft Inc. 2010 06/10
Actual
material certificates
and certificate of conformance
supplied as standard to
EN 10204:2004 3.1
ZERO ADJUST
VENT PLUG
HEAT NUMBER
TRACEABILITY