Tank Temperature Check

Turn on brewer at the control panel ON/OFF button. Press and hold

ƒ

button (see illustration, page 2) for 5 seconds. Water Temperature will

be displayed (temperature in heating tank).

Error Message

With the G3/Gold Cup Series brewers, there are three error messages that can appear on the screen to advise the user of a malfunction. If one

of these error messages appear, the brewer will lock up and stop functioning until the error is corrected. An error message will occur under the

following conditions:

1. Water level fill error or overflow. This error message occurs when the inlet valve solenoid has been on for more than

10 minutes. This error message also occurs when the valve is refilling the tank during a brew cycle for more than 1½

minutes.

2. Water temperature control system error. An open probe or a break in the temperature control circuit is detected.

3. This error message indicates there is an overheating problem. The sensor is reading that temperature in the heating

tank has risen above 210ºF.

Usually the screen will display a service call phone number. Once a malfunction is corrected, the error message must be

cleared. To reset the control panel and return to normal operation, press the  button for 5 seconds.

(800) 000-000

Over Temp Error

(800) 000-000

Sensor Err

(800) 000-000

Water Level Err

P-Maintenance

Beeper On/Off

Exit

Quality Timer

Display Brew

Time

Cold Brew Lock (Factory set to 5º F)

Press to select, < or > to select desired setting (CBL 5, 15 or OFF), to set.

The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point.

The first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of

set point for the Ready to Brew message, however it will brew at any temperature.

Master Reset

Press to display Are You Sure? Then < for Yes, > for No. When Master Reset is used, the all of the menu selec-

tions in the UCM return to factory defaults.

Service Call (Phone number Factory set to 1-800-000-0000)

Press to display number and change number or < to move place and EX to exit when complete. This number will

be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.

Access Code (Factory set to 1-2-3-4)

Press to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit

when complete.

Banner Name (Factory setting reads CURTIS)

Press to display the current banner letters. Press < or > to move cursor, press to select letters, or EX to exit

when complete. This feature allows up to 14 letters to be programmed. Programming all blanks disables Banner

Name. When a banner is set, the banner name is displayed on line one and Ready to Brew is on the second line.

P-Maintenance (Factory set to OFF)

Press to Select, Set gallons brewed to indicate P-Maintenance. Press < or > to adjust from Off to 3000 gallons.

Press to exit.

Beeper On/Off (Factory set to ON)

Press to display ON or OFF. Pressing either < or > toggles between on and off. to set. When ON, this feature

allows you to hear a short beep each time a button is pressed.

Quality Timer (Factory set to OFF)

Press to Select. By pressing < or > buttons, you can increase and decrease time. Setting range is from 0 to 10

hours in 1 hour increments. Press to set. Expired time indicated by audio alarm and flashing “Quality Timer”.

Display Brew Time (Factory set to ON)

Press to Select. Pressing < or > toggles between ON and OFF.

Exit

Press to select, exits program mode and returns unit to operation. Pressing > returns you to Tea Recipes.

Master Reset

Service Call

Cold Brew Lock

Access Code

Banner Name