Wilbur Curtis RTB30061 User Manual
Page 4

4
Tank Temperature Check
Turn on brewer at the control panel ON/OFF button. Press and hold
button (see illustration, page 2) for 5 seconds. Water Temperature will
be displayed (temperature in heating tank).
Error Message
With the G3/Gold Cup Series brewers, there are three error messages that can appear on the screen to advise the user of a malfunction. If one
of these error messages appear, the brewer will lock up and stop functioning until the error is corrected. An error message will occur under the
following conditions:
1. Water level fill error or overflow. This error message occurs when the inlet valve solenoid has been on for more than
10 minutes. This error message also occurs when the valve is refilling the tank during a brew cycle for more than 1½
minutes.
2. Water temperature control system error. An open probe or a break in the temperature control circuit is detected.
3. This error message indicates there is an overheating problem. The sensor is reading that temperature in the heating
tank has risen above 210ºF.
Usually the screen will display a service call phone number. Once a malfunction is corrected, the error message must be
cleared. To reset the control panel and return to normal operation, press the button for 5 seconds.
(800) 000-000
Over Temp Error
(800) 000-000
Sensor Err
(800) 000-000
Water Level Err
P-Maintenance
Beeper On/Off
Exit
Quality Timer
Display Brew
Time
Cold Brew Lock (Factory set to 5º F)
Press to select, < or > to select desired setting (CBL 5, 15 or OFF), to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point.
The first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of
set point for the Ready to Brew message, however it will brew at any temperature.
Master Reset
Press to display Are You Sure? Then < for Yes, > for No. When Master Reset is used, the all of the menu selec-
tions in the UCM return to factory defaults.
Service Call (Phone number Factory set to 1-800-000-0000)
Press to display number and change number or < to move place and EX to exit when complete. This number will
be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1-2-3-4)
Press to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit
when complete.
Banner Name (Factory setting reads CURTIS)
Press to display the current banner letters. Press < or > to move cursor, press to select letters, or EX to exit
when complete. This feature allows up to 14 letters to be programmed. Programming all blanks disables Banner
Name. When a banner is set, the banner name is displayed on line one and Ready to Brew is on the second line.
P-Maintenance (Factory set to OFF)
Press to Select, Set gallons brewed to indicate P-Maintenance. Press < or > to adjust from Off to 3000 gallons.
Press to exit.
Beeper On/Off (Factory set to ON)
Press to display ON or OFF. Pressing either < or > toggles between on and off. to set. When ON, this feature
allows you to hear a short beep each time a button is pressed.
Quality Timer (Factory set to OFF)
Press to Select. By pressing < or > buttons, you can increase and decrease time. Setting range is from 0 to 10
hours in 1 hour increments. Press to set. Expired time indicated by audio alarm and flashing “Quality Timer”.
Display Brew Time (Factory set to ON)
Press to Select. Pressing < or > toggles between ON and OFF.
Exit
Press to select, exits program mode and returns unit to operation. Pressing > returns you to Tea Recipes.
Master Reset
Service Call
Cold Brew Lock
Access Code
Banner Name