Wilbur Curtis RTB30061 User Manual
Page 3

3
Program Menus
Program Menus
Tea By Volume
Tea Recipes
Tea By Time
Program Menus screen. Press the > button to show the next menu item.
Tea Recipes (Factory set to Standard Tea Purple)
Press to Select. Press < or > to scroll through recipes: Standard Gray, Standard Purple, Tropical Gray, Tropical
Purple, 76/308 Gray or 76/308 Purple. Press to set.
Tea Dilut Volume
Tea Dilut Delay
Tea Dilut Time
Tea by Volume: Press to select, Display will now show Push START To Begin... Press the BREW button then hot
water starts running, when desired volume is reached press BREW button again to stop the flow. Now the volume has
been set. Pressing > button will display the subsequent menu features.
Tea by Time (Factory set to 5:52 LARGE, 2:56 SMALL)
Press to select. By pressing < or > buttons, you can increase and decrease time. Press to set minutes and
seconds.
Tea Dilution Delay (Factory set to 0:30)
Press to Select. Press < or > buttons, to add or decrease time. Press to set. The maximum is 10 minutes.
Tea Dilution Volume: Press to Select, Display will now show Select Button... Press the desired brew button and
water will flow, when required volume is reached press BREW button again to stop the flow. Now the volume has
been set. Press > to display subsequent menu features.
Dilution Time (Factory set to 4:05 LARGE, 2:02 SMALL)
Press to Select. By pressing < or > buttons, you can increase and decrease time. Press to set minutes and
seconds. The maximum is 9 min, 59 sec.
Tea Dilution Stir (Factory set to ON).
Press to Select. Press < or > to select ON or OFF.
Tea Pulse Brew (Factory set to OFF).
Press to Select. Press < or > to select ON, OFF or D. D is a manual adjust from 1 to 20 pulses with an ON time
from 5 to 150 seconds and an OFF time from 5 to 150 seconds.
Tea Fast Brew (Factory set to OFF).
Press to Select, press < or > to choose ON or OFF. Selecting ON will start hot water spraying in the brewcone first
and then 1 minute later the dilution water will start to flow.
Tea Drip-Out (Factory set to OFF)
Press to Select. Press < or > to adjust time. Settings are OFF, up to 15 minutes, at 5 second increments.
Temperature (Factory set to 204ºF)
Press to Select. Press < or > to increase or decrease setting. Temperature range, from 170ºF to 208ºF in 2-degree
increments.
Energy Save Mode (Factory set to OFF)
Press to Select, < or > ON, OFF or ON 140ºF , to set. When in ON, unit will automatically shut off 4 hours
from last brew. When feature is OFF, unit does not have the energy saving mode.
In the ON 140ºF position, temperature goes down to 140ºF if unit has not brewed in 4 hours. This feature will save
energy by maintaining a lower temperature in the tank during periods of non-operation.
Brew Count Odom.
Press to Select, Shows total gallons and total brew cycles on the unit. Press ex or Reset Brew Count Total.
Brew Count Total
Press to Select, Shows total gallons and total brew cycles on the unit. Cannot be reset.
Continued on Page 4
Temperature
Tea Dilut Stir
Energy Save Mode
Brew Count Odom
Brew Count Total
Tea Pulse Brew
Tea Fast Brew
Tea Drip-Out