With G3/Gold Cup Series brewers, there are three error messages that can appear on the screen to advise the user of a malfunction. If one of
these error messages appear, the brewer will lock up and stop functioning until the error is corrected.
An error message will occur under the following conditions:
1. Water level fill error or overflow. This error message occurs when the inlet valve solenoid has been on for more
than 10 minutes. This error message also occurs when the valve is refilling the tank during a brew cycle for
more than 1½ minutes.
2. Water temperature control system error. An open probe or a break in the temperature control circuit is detected.
The screen may display a phone number to call for service. After the malfunction is corrected, the error message
must be cleared. To reset the control panel and return to normal operation, press for 5 seconds.
Tank Temperature Check
Turn on brewer at the control panel ON/OFF button. Press and hold
the button (arrow) for 5 seconds. The water temperature in the heating
tank will be displayed on the screen. Press to exit.