Programming

Error Message

With G3/Gold Cup Series brewers, there are three error messages that can appear on the screen to advise the user

of a malfunction. If one of these error messages appear, the brewer will lock up and stop functioning until the error is

corrected.
An error message will occur under the following conditions:

1. Water level fill error or overflow. This error message occurs when the inlet valve solenoid has

been on for more than 10 minutes. This error message also occurs when the valve is refilling

the tank during a brew cycle for more than 1½ minutes.

2. Water temperature control system error. An open probe or a break in the temperature control

circuit is detected.

3. Excess temperature. The temperature sensor is reading that the temperature in the heating

tank has risen above 210ºF.

The screen may display a phone number to call for service. After the malfunction is corrected, the

error message must be cleared. To reset the control panel and return to normal operation, press

for 5 seconds.

(800) 000-000

Sensor Err

(800) 000-000

Water Level Err

Tank Temperature Check

Turn on brewer at the control panel ON/OFF button. Press and hold

ƒ

button (see illustration, page 3) for 5 sec-

onds. Water Temperature will be displayed (temperature in heating tank).

(800) 000-000

Over Temp Err

Exit

Display Brew Time (Factory set to ON)

Press to Select. Pressing < or > toggles between ON and OFF.

Display Messages (Factory set to ON)

Press to display ON or OFF. Pressing either < or > toggles between on and off. This feature allows the operator to

select the message “Rinse Server Before Brewing”. This will be displayed any time the unit is not brewing.

Model Select (Factory set to TEA/IC-1BATCH)

Press to select, < or > to select model. The selections are: TEA/IC-1BATCH, TEA/IC-2BATCH, TEA/1C-3BATCH,

TEA/IC-4BATCH, TEA-SWEET, DUAL DILUTION, DUAL-SWEET, COMBO, COMBOSWEET. Press to set. When

the Model Select feature is changed, all settings are reset to the defaults of the newly selected model.

Exit

Press to select, exits program mode and returns unit to operation. Pressing > returns you to Tea Recipes.

Display Brew

Time

Model Select

Display Messages