Programming
P‑Maintenance
Beeper On/Off
Quality Timer
Tea Drip-Out (Factory set to OFF)
Press to Select. Press < or > to adjust time. Settings are OFF, up to 15 minutes, at one minute increments.
Temperature (Factory set to 204ºF)
Press to Select. Press < or > to increase or decrease setting. Temperature range, from 170ºF to 208ºF in 2-degree
increments.
Energy Save Mode (Factory set to OFF)
Press to Select, < or > ON, OFF or ON 140ºF , to set. When in ON, unit will automatically shut off 4 hours from
last brew. When feature is OFF, unit does not have the energy saving mode.
In the ON 140ºF position, temperature goes down to 140ºF. if unit has not brewed in 4 hours. This feature will save
energy by maintaining a lower temperature in the tank during periods of non-operation.
Brew Count Odom.
Press to Select, Shows total gallons and total brew cycles on the unit. Press ex or Reset Brew Count Total.
Brew Count Total
Press to Select, Shows total gallons and total brew cycles on the unit. Cannot be reset.
Cold Brew Lock (Factory set to 5º F)
Press to select, < or > to select desired setting (CBL 5, 15 or OFF), to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point.
The first setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of
set point for the Ready to Brew message, however it will brew at any temperature.
Master Reset
Press to display Are You Sure? Then < for Yes, > for No. When Master Reset is used, the all of the menu selec-
tions in the UCM return to factory defaults.
Service Call (Phone number Factory set to 1-800-000-0000)
Press to display number and change number or < to move place and EX to exit when complete. This number will
be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1-2-3-4)
Press to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit
when complete.
Banner Name (Factory set to CURTIS)
Press to display letters and change letters or < to move place and EX to exit when complete. This feature allows up
to 14 letters to be programmed for company name or regional name. Programming all blanks disables Banner Name. If
programmed, Banner Name is displayed every 5 sec. on and off.
P-Maintenance (Factory set to OFF)
Press to Select, Set gallons brewed to indicate P-Maintenance. Press < or > to adjust from Off to 3000 gallons.
Press to exit.
Beeper On/Off (Factory set to ON)
Press to display ON or OFF. Pressing either < or > toggles between on and off. to set. When ON, this feature
allows you to hear a short beep each time a button is pressed.
Quality Timer (Factory set to OFF)
Press to Select. By pressing < or > buttons, you can increase and decrease time. Setting range is from 0 to 10
hours in 1 hour increments. Press to set. Expired time indicated by audio alarm and flashing “Quality Timer”.
Temperature
Energy Save Mode
Brew Count Odom
Master Reset
Service Call
Brew Count Total
Cold Brew Lock
Access Code
Banner Name
Tea Drip‑Out