beautypg.com

Wilbur Curtis D1000GT User Manual

Page 3

background image

3

Program Menus

From Program Menus press > display will now show the next feature.

Selecting Brew by Volume or Brew by Time depends on whether you know your brew time before starting.

Brew by Volume (Factory set to 74 oz)

Press  to Select, display will now show Select Button. Select desired Brew button. To Begin... Press the BREW button then hot water

starts running, when correct volume is reached press BREW button again to stop the flow. Now the volume has been set. Pressing >

button will display the subsequent menu features.
Brew by Time (Factory set to 3 min – 0 sec)

Press  to Select, display will now show Select Button. The current time is now shown. By pressing < > you can toggle back and forth

from minutes to seconds to exit (ex). Change the time or set and exit by pressing .
Temperature (Factory set to 200°F)

Press  to Select. Press < > to move to desired temperature and then  to set. Temperature is programmable from 170ºF to 206ºF

in 2-degree increments.
Energy Save Mode (Factory set to OFF)

Press  to Select. Press < > to select ON or OFF,  to set. When in ON, unit will automatically shut off 4 hours from last brew.

When feature is OFF, unit does not have the energy saving mode. In the ON 140ºF position, temperature goes down to 140ºF if unit

has not brewed in 4 hours. This feature will save energy by not heating the tank during periods of non-operation.
Brew Count Odom.

Press  to display total gallons brewed. Press ex or Reset
Pre-Infusion (Factory set to OFF)

Press  to Select. Display will now show Select Button. Select desired Brew button. Current setting in seconds is displayed < to

decrease or select > to increase (range from OFF to 10 through 60 seconds),  to set.
If Pre-infusion is selected (ON), Cold Brew Lock is set to Delta 1 within 5ºF of set point and Cold Brew Lock and Pulse Brew disappears

from the list of program selections.

Temperature

Brew By Time

Brew By Volume

Program Menus

Energy Save Mode

Brew Count Odom

Pulse Brew Continued on Page 4

Each brew button volume is independently programmable for Brew Volume (volume or time), Pre-infusion, and

Pulse Brew. During actual brew cycle a 2-minute drip mode is added to the brew time.

Brew Count Total

Press  to Select, Shows total gallons and total brew cycles on the unit. Cannot be reset.
Cold Brew Lock . . . (Factory set to 5º)

Press  to select, < > to select desired setting (CBL 5, 15 or OFF), to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The first setting is

within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of set point for the Ready to Brew mes-

sage, however it will brew at any temperature.
Master Reset

Press  to display Are You Sure?

Then < for Yes, > for No.

Brewer factory defaults are then reset.
Service Call (Phone number Factory set to 1-800-000-0000)

Press  to display number and change number or < to move place and EX to exit when complete This number will be displayed dur-

ing a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1-2-3-4)

Press  to display number and change number, (the number can be change 1 to 4) or < to move place and ex to exit when complete.

Banner Name (Factory set to Curtis)

Press  to display current banner. Press < > to move place and EX to exit when complete. This feature allows up to 14 letters to

be programmed for company name or regional name. Programming all blanks disables Banner Name. Once the banner has been

programmed, the words will be displayed during normal operation, above the words Ready to Brew.

P-Maintenance (Factory set to OFF)

Press  to Select, Set gallons brewed to indicate P-Maintenance. Press < > to adjust from Off to 3000 gallons. Press  to exit.

Beeper On/Off (Factory set to ON)

Press  to display ON or OFF. Pressing either < > toggles between on and off. to set.

Pulse Brew (Factory set to OFF)

Press  to select. Display will now show Select Button. Select desired Brew button to program. The next screen will prompt you to

press < > to select OFF or one of four pulse patterns (A to E) .

Master Reset

Service Call

Access Code

Banner Name

P-Maintenance

Pre-Infusion

Brew Count Total

Cold Brew Lock

Beeper On/Off

Pulse Brew

On/Off