beautypg.com

E-90 troubleshooting – Casio 575E1A User Manual

Page 92

background image

E-90

Troubleshooting

Problem

Possible Cause

Action

See page

Nothing happens when the
LAYER or SPLIT button is
pressed.

No sound is produced when
playing MIDI data from a
computer.

Playing on the digital piano
produces an unnatural sound
when connected to a computer.

Cannot record chord
accompaniment data on a
computer.

The digital piano starts up
abnormally when it is turned
on.

A downloaded tone with
waveform contains noise or
digital piano operations become
abnormal when user data is
selected.

1. One or more of the melody

channels (2 through 4) is turned
off.

2. The volume setting of one or

more of the melody channels (2
through 4) is too low.

3. The digital piano is in record

standby.

4. The SMF Player Mode is currently

being use.

1. USB cable is not connected

properly.

2. Channel is turned off, or volume

setting is too low.

The computer’s MIDI Thru function
is turned on.

Accomp/Song MIDI Out is turned
off.

1. Flash memory is corrupted. There

is something wrong with the card.

2. The digital piano detected

abnormal flash memory data and
is automatically resetting the
digital piano system.

Someone may have turned off the
digital piano while data was being
stored in Flash memory or
something else has caused Flash
memory contents to become
corrupted for some reason.

1. Use the Mixer to turn on

Channels 2 through 4.

2. Use the Mixer to raise the volume

setting of Channels 2 through 4.

3. The LAYER and SPLIT buttons

are disabled during recording
and record standby.

4. Turn off the SMF Player Mode.

LAYER and SPLIT are not
available while the SMF Player
Mode is in use.

1. Connect USB cable properly.

2. Use the Mixer to turn the channel

on, or raise the volume setting.

Turn off the MIDI Thru function on
the computer or turn off Local
Control on the digital piano.

Turn on Accomp/Song MIDI Out.

1. a. Disconnect the AC adaptor and

press the POWER button.

b. Reconnect the AC adaptor, and

then press the POWER button
again to turn on power.

c. Use the TRANSPOSE/

FUNCTION button to perform
the system reset operation.
• If this does not solve the

problem, contact your
nearest authorized CASIO
Service Provider to request
repair.

2. Wait (about 40 seconds) until the

“Pls Wait” message disappears
from the display.

Use the TRANSPOSE/FUNCTION
button to perform the system reset
operation. If this does not correct
the problem, contact your nearest
authorized CASIO Service Provider
to request maintenance.

E-39

E-40

E-63, 64

E-72

E-78

E-39, 40

E-71

E-71

E-14

E-71

E-71

This manual is related to the following products: