8
FORM NO. L-20210-B-1209
O-RING & BACK-UP RING REPLACEMENT
REFER TO FIGURES 9 & 10.
1. Separate Cylinder (Item 2) and Piston (Item 3).
2. Remove O-rings (Items 12 & 13) and Back-up Rings
(Items 23 & 25) from Cylinder and Piston.
3. Clean o-ring grooves of Cylinder and Piston; then
lubricate new o-rings and o-ring grooves of Piston
and Cylinder with fresh o-ring lubricant.
4. Install new O-rings (Items 12 & 13) and Back-up
Rings (Items 23 & 25).
NOTE
When installing new O-rings and Back-up
Rings, make sure curved surface of Back-up
Ring matches surface of O-ring. Back-up Rings
must be installed on the non-pressurized side
of the O-rings.
5. Carefully slide Piston (Item 3) into Cylinder (Item 2)
to avoid damaging seals.
FIGURE 9
Cylinder
Piston
23
12
13
25
FIGURE 10
12
23
13
25
5H20P REASSEMBLY
REFER TO FIGURES 11 & 12.
1. Slide Drive Ring (Item 4) into Cylinder/Piston
Assembly.
2. Lubricate splines of Hub (Item 1) with NEVER
SEEZ
®
.
FIGURE 11
FIGURE 12
11
Cylinder/Piston
Lubricate with
Never-Seez®
1
4
6
7
Cylinder/Piston
Assembly
Drive Flange
Assembly
Retaining Ring
(Item 11)
3. Slide Hub (Item 1) into Drive Ring (Item 4), and
replace Retaining Ring (Item 11).
4. Install Compression Springs (Item 7) into respective
holes of Drive Ring (Item 4).
5. Slide Backing Plate (Item 6) onto Hub (Item 1).
6. Slide Drive Flange Assembly onto Hub (Item 1) and
Cylinder/Piston Assembly.
7. Replace Retaining Ring (Item 11).
CAUTION
Working with spring loaded or tension
loaded fasteners and devices can cause
injury. Wear safety glasses and take the
appropriate safety precautions.