7. Standard Configuration:
Attach the Quick Exhaust Valve (Item 23) to the brake.
Use Teflon tape and/or pipe sealant on the threads.
With Optional Solenoid:
If you are using the optional Solenoid Valve
(Nexen Part #964650), the Quick Exhaust Valve is
unnecessary. Assemble the optional Solenoid Valve
directly to the brake using the supplied fittings. Use
Teflon tape and/or pipe sealant on the threads.
NOTE: Align the air inlet ports in the down position
to allow condensation to drain out of the air
chamber.
8. Attach the air line to the valve.
9. If using optional solenoid valve, attach DIN Connector
cable to valve by pressing DIN Connector onto valve
power pins and tightening DIN Connector fastener.
Then connect DIN Connector cable wires using the
following chart to the appropriate power supply, see
Table 3.
Table 3
Optional Solenoid Valve Specifications
Voltage
Power
Resistance
Current Cv
24 VDC
4 W
145 ohms
.17 A
.25
CAUTION
24 VDC valve connector has a
suppression diode installed across the
coil. Observe proper voltage polarity or
connector damage will result.
DANGER
Support the load before disengaging
the brake. Failure to support the load
could result in serious bodily injury.
CAUTION
The Ball Screw Brake will disengage if you
depress the domed button at the top of the
Solenoid Valve (if air pressure is applied).
The LED will illuminate when the Solenoid
Valve is actuated and the Ball Screw
Brake is disengaged. Pressure needed to
disengage should NOT exceed 80 psi.
DIN Connector Cable
Wire Color
Valve
24 VDC
Valve Pin
Brown
+
1
White
-
2
Green
Ground
Ground
FIGURE 5 Optional Solenoid Valve Part #964650.
Exhaust
Silencer
To Brake
Air Supply
Tube Fitting
Manual
Override
DIN
Connector
Lead Wires
1/8 NPT