Nexen BSB07 965040 User Manual
Page 11
11
FORM NO. L-21225-F-0813
TROUBLESHOOTING
Problem
Probable Cause
Solution
Failure to engage (brake)
Weak or broken springs
Replace broken springs
Failure to disengage (1)
Control valve malfunction -
air not getting to brake
Check for low air pressure or replace the
control valve.
NOTE: The Unit has been designed to
release before (at or below) 5.5 bar [80
psi] Required disengagement pressure
higher than 5.5 bar [80 psi] may indicate
improper assembly.
Failure to disengage (2)
Air is leaking around the O-ring seals.
Replace the O-rings.
Loss of torque
Fraction Facing is worn or dirty.
Replace friction face.