REQUIRED TOOLS

• Clean, pressurized air
• Mounting bolts and appropriate wrench
(See Table 1)

AIR PREPARATION

• Air valve
• Air fitting
• Quick exhaust valve (optional)

All Nexen pneumatically actuated devices require clean and dry air, which meets or exceeds ISO 8573.1:2001 Class
4.4.3 quality.

NOTE: Lubricated air may be used, but it is not required. The seals in all Nexen Rail Brakes are lubricated at the

factory to ensure optimal performance and a long product life.

The most effective and economical way to lubricate Nexen Rail Brakes is with an Air Line Lubricator, which injects

oil into the pressurized air, forcing an oil mist into the air chamber.

Synthetic lubricants are not recommended.

DANGER

WARNING

While lubricated air will keep the seals well

lubricated, it may wash away the factory-applied

lubrication over time. For this reason, once

lubricated air is used with a Nexen Rail Brake,

it must always be used. Discontinuing use of

lubricated air may cause seal failure, resulting in

an inability to disengage the brake.