5
*HIGH FORCE SETTINGS – AS SHIPPED WITH BOTH INSIDE AND
OUTSIDE ECCENTRICS ON BOTH ENDS OF VIBRATOR.
**LOW FORCE SETTINGS – REMOVE INSIDE ECCENTRIC ON BOTH
ENDS OF VIBRATOR. REMOUNT OUTSIDE ECCENTRIC AND LINE UP
NUMBER WITH ARROW ON SHAFT.
Trouble Shooting
A. VIBRATOR DOES NOT START:
1) Short in lines
2) Burned out overload protection
3) Short in winding, check with ohmmeter
B. VIBRATOR OVERLOAD POSSIBLE CAUSES:
1) Bolts holding vibrator are loose
2) Excessive ambient heat
3) One phase open (check: a) power source; b) wiring)
4) Bad bearings
Note:
Always make sure the data stamped on nameplate
corresponds to power sources.
WHEN INQUIRING ABOUT ANY VIBRATOR, ALWAYS REFER TO
THE SERIAL NUMBER STAMPED ON THE METALFAB NAMEPLATE.