beautypg.com

Vibrator force adjustment – Metalfab Bin Activator User Manual

Page 4

background image

4

2. Because the Bin Activator and the motor vibrate, the electrical connections

must be made with flexible lead. Braided neoprene covered cable is
recommended.

3. Refer to wiring diagram in motor conduit box for wiring instructions.

Vibrator Force Adjustment

Warning: Vibrator must be electrically locked-out before any

adjustment or maintenance can be performed.

1. The centrifugal force setting of the vibrator is set at the factory for the

minimum force level that will produce flow of product. If flow is not
instantaneous or continuous, it may be necessary to increase the centrifugal

force. To do so, the following procedure should be followed:

1) Remove the bolts of both the upper and lower end covers.

2) Remove end covers exposing the four (4) eccentric weights.

Note:

The (2) OUTER weights on the

INVICTA

Explosion Proof

and the

METALFAB

TENV Vibrators are the weights to be

adjusted. The (2) INNER weights on the

INVICTA

TENV

Vibrators are the weights to be adjusted.

2. To increase the force setting, loosen the clamping bolt on the two (2) weights

that will be adjusted. (See note above).

3. Refer to the applicable vibrator operation and maintenance instructions for

force settings and technical information.

4. As the centerline of the adjusted weights approach the centerline of the fixed

weights, the centrifugal force is increased. When the weights centerline is
opposed, the centrifugal force decreases. If the centerlines of all four (4)

weights are completely aligned, you will develop the maximum force available

for that size vibrator.

5. Regardless of which vibrator you have, when you have completed your force

adjustment, the OUTER weights should be in line with each other and the

INNER weights should be in line with each other. ANY OTHER
ARRANGEMENT WILL RESULT IN A MOTION THAT CAN DAMAGE THE

VIBRATOR AND BE VERY DETRIMENTAL TO THE APPLICATION, WELDS OF

THE BIN ACTIVATOR AND SUPPORT STRUCTURES.

6. Assemble the unit by reversing the procedure outline as above.