beautypg.com

2 model identification, 3 warranty, 4 dimensions – Bradford White BMT2V0400 User Manual

Page 4: 5 locating the appliance

background image

B

radford

W

hite

C

orp.

Page 4

1.2 Model Identification

Consult the rating plate on the unit. The

following information describes the model number

structure.

Model Character Designation

1-4 Model Series Designation

B M T 2 = Bradford White, Brute Deluxe

5 Usage

H = Hydronic

V = Volume Water

6-9 Size

0 2 0 0 = 199,900 BTU/h input

0 3 0 0 = 300,000 BTU/h input

0 4 0 0 = 399,900 BTU/h input

10 Fuel

N = Natural Gas

P = Propane

11 Location

C = Indoor and Outdoor

12 Firing Mode

C = On-Off (standard)

K = Two-stage (optional)

13 Revision

2 = Revision Level 2

14 Heat Exchanger

B = Glass-lined CI / copper / brz trim (std. MT2V)

C = Glass-lined cast iron / copper (std. MT2H)

N = Glass-lined cast iron / cu-nickel

P = Glass-lined cast iron / cu-nickel / brz trim

2 = Glass-lined cast iron / copper, brz trim, HLW

5 = Glass-lined cast iron / cu-nickel / brz, HLW

15 Options Code

X = Standard unit

L = Low temperature control (std. MT2V)

16 Pump Options

X = No Pump

N = Pump mounted, normal water, Taco

S = Pump mounted, soft water pump (MT2V

only), Taco

G = Pump mounted, normal water, Grundfos

1.3 Warranty

Bradford White's Brute Deluxe appliances are

covered by a limited warranty. The owner should

fill out the warranty registration card and return it to

Bradford White.

All warranty claims must be made to an

authorized Bradford White. representative or directly

to the factory. Claims must include the serial number

and model (this information can be found on the rating

plate), installation date, and name of the installer.

Shipping costs are not included in the warranty

coverage.

Some accessory items are shipped in separate

packages. Verify receipt of all packages listed on

the packing slip. Inspect everything for damage

immediately upon delivery, and advise the carrier of

any shortages or damage. Any such claims should be

filed with the carrier. The carrier, not the shipper, is

responsible for shortages and damage to the shipment

whether visible or concealed.

1.4 Dimensions

See Figures 1A and 1B.

1.5 Locating the Appliance

The appliance should be located to provide

clearances on all sides for maintenance and inspection.

It should not be located in an area where leakage of

any connections will result in damage to the area

adjacent to the appliance or to lower floors of the

structure.

When such a location is not available, it is

recommended that a suitable drain pan, adequately

drained, be installed under the appliance.

The appliance is design certified by CSA-

International for installation on combustible flooring;

in basements; in closets, utility rooms or alcoves.

Brute Deluxe Boilers or Water Heaters must never

be installed on carpeting. The location for the

appliance should be chosen with regard to the vent

pipe lengths and external plumbing. The unit shall be

installed such that the gas ignition system components

are protected from water (dripping, spraying, rain, etc.)

during operation and service (circulator replacement,

control replacement, etc.). When vented vertically, the

M T 2

C

2

SERIES

M T 2

USAGE

H
V

SIZE

0 2 0 0

0 3 0 0

0 4 0 0

FUEL

N
P

FIRING

MODE

C
K

LOCATION

C

REVISION

2

HEAT

EXCHANGER

B
C
N
P

2
5

OPTIONS

CODE

X
L

PUMP

OPTIONS

X
N
S

G

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

B

B

This manual is related to the following products: