Vj u 2 b, 1c. heater identification, Boiler assembly and placement 2a. field assembly – Bradford White BJVS225 User Manual
Page 4: Bradford white corp

Bradford White Corp
Page 4
1C. Heater Identification
Consult the rating plate on the boiler. The following
example simplifies the heater identification:
SECTION 2.
Boiler Assembly and Placement
2A. Field Assembly
These boilers are available in two configurations; the
JVH has a hot surface ignition pilot and integral draft
fan, and the JVS has an electronic intermittent ignition
device (I.I.D.). Look for the model designation on the
rating plate, which can be found on top of the boiler in
the right rear corner.
The Bradford White automatic vent dampers are
standard on all JVS models. The Bradford White
side wall power venters can be used on JVS models.
Special instructions for their installation are included
in the vent damper and power venter package. Read
them carefully before installation.
JVS
1
st
thru
3
rd
C
haraCters
(M
odel
d
esignation
)
BJV = B
radford
W
hite
C
orp
. M
odel
JV
B
rute
M
ini
4
th
C
haraCter
(i
gnition
s
ysteM
)
s = s
park
i
gnition
h = h
ot
s
urfaCe
p
ilot
5
th
thru
7
th
C
haraCters
(s
ize
)
i
nput
MBtu / h
8
th
C
haraCter
(
fuel
)
n = n
atural
g
as
p = p
ropane
g
as
9
th
C
haraCter
(f
iring
s
ysteM
)
D =
on
/
off
10
th
C
haraCter
(C
onstruCtion
o
ption
)
i = (s
tandard
)
J = p
uMp
(050-125
only
)
11
th
C
haraCter
(a
ltitude
in
f
eet
)
s = (0 - 2,000) n
atural
or
(0 - 5,000) p
ropane
h = (2,001 - 5,000) n
atural
i = (5,001 - 8,000) n
atural
and
p
ropane
J = (8,001 - 10,000 n
atural
and
p
ropane
12
th
C
haraCter
(C
ountry
)
u = usa & C
anada
13
th
C
haraCter
(r
eVision
)
2 = s
eCond
r
eVision
JVH
1
st
thru
3
rd
C
haraCters
(M
odel
d
esignation
)
BJV = B
radford
W
hite
C
orp
. M
odel
JV
B
rute
M
ini
4
th
C
haraCter
(i
gnition
s
ysteM
)
s = s
park
i
gnition
h = h
ot
s
urfaCe
p
ilot
5
th
thru
7
th
C
haraCters
(s
ize
)
i
nput
MBtu / h
8
th
C
haraCter
(
fuel
)
n = n
atural
g
as
p = p
ropane
g
as
9
th
C
haraCter
(f
iring
s
ysteM
)
C =
on
/
off
10
th
C
haraCter
(C
onstruCtion
o
ption
)
s = s
tandard
11
th
C
haraCter
(a
ltitude
in
f
eet
)
s = (0 - 2,000) n
atural
or
(0 - 5,000) p
ropane
h = (2,001 - 5,000) n
atural
i = (5,001 - 8,000) n
atural
and
p
ropane
J = (8,001 - 10,000 n
atural
and
p
ropane
12
th
C
haraCter
(C
ountry
)
u = usa & C
anada
13
th
C
haraCter
(r
eVision
)
2 = s
eCond
r
eVision
MODEL
J V
IGNIT
SYST
S
H
SIZE
0 5 0
0 7 5
1 0 0
1 2 5
1 6 0
2 2 5
FUEL
N
P
FIRING
SYST
C
D
CONST
OPTION
S
P
I
J
ALTITUDE
S
H
I
J
REVISION
2
BRADFORD
WHITE
COUNTRY
U
V
J
U
2
B
Table 1. Boiler Model Identification.
1
2
4
5
6
7
8
9
10
11
12
13
3