Honeywell gas control troubleshooting chart, Flammable vapor ignition resistant water heaters – Bradford White UDH-75T-50FR-3N User Manual

Page 5

background image

Honeywell Gas Control Troubleshooting Chart

LED Status

Control Status

Probable Cause

Five flashes and

three second pause

Thermostat/well sensor fault.

Gas Control electronic fault detected.

Seven flashes and

three second pause

Eight flashes and

three second pause

Standing pilot remains on while set
point knob is in “OFF” position.

1. Damage to the temperature sensor.
2. Temperature sensor resistance out of
range.

1. Control needs to be reset.
2. Control is wet or physically

damaged.

Pilot valve stuck in open position.

Service

Procedure

1. See service
procedure V

1. Reset Gas Control
2. Replace Gas

Control.

Replace Gas Control.

Flammable Vapor Ignition Resistant Water
Heaters

Green LED Indicator

Observe green LED indicator on
Gas Control. Error flash codes are
displayed with a three second pause
before repeating. Check and repair
the system as noted in the
troubleshooting table below.

5

Water leak detected by accessory
module.

Six flashes and

three second pause

Excessive amount of water in drain
pan/water dam.

1. Check T&P valve
2. Check all water

fittings.

3. Pressurize and leak

test tank.

5