MAINTENANCE
WARNING
Water heaters are heat producing appliances. To avoid damage or injury
there shall be no materials stored against the water heater or vent-air intake
system, and proper care shall be taken to avoid unnecessary contact
(especially by children) with the water heater and vent-air intake system.
UNDER NO CIRCUMSTANCES SHALL FLAMMABLE MATERIALS,
SUCH AS GASOLINE OR PAINT THINNER BE USED OR STORED IN
THE VICINITY OF THIS WATER HEATER, VENT-AIR INTAKE SYSTEM
OR IN ANY LOCATION FROM WHICH FUMES COULD REACH THE
WATER HEATER OR VENT-AIR INTAKE SYSTEM.
The following maintenance should be performed by a qualified service
technician at the minimum periodic intervals suggested below. In some
installations, the maintenance interval may be more frequent depending on
the amount of use and the operating conditions of the water heater. Regular
inspection and maintenance of the water heater and vent-air intake system
will help to insure safe and reliable operation.
1. Annually check the operation of the thermostat.
2. The flow of combustion and ventilation air MUST NOT be restricted.
Clear the combustion air openings of any dirt, dust, or other restrictions.
3. At all times keep the water heater area clear and free from combustible
materials, gasoline and other flammable vapors and liquids.
IMPORTANT
The water heater should be inspected at a minimum annually by a
qualified service technician for damaged components and/or joints
not sealed. DO NOT operate this water heater if any part is found
damaged or if any joint is found not sealed.
WARNING
The ventilation air system may be HOT.
4. Bi-annually conduct a visual check of the main and pilot burner flames to
determine that they are burning properly. See Burner Flame Check
section on page 21.
22