Gas Conversion Instructions continued-
3. Change the pilot regulator by removing pilot regulator cap. Depress and
rotate knob counterclockwise
to the NAT. setting using a screwdriver.
Replace cap.
4. Remove the outer door. Remove, or slide open, the inner door.
5. Disconnect thermocouple, gas supply tube and pilot tube from the gas
valve and remove the burner assembly from the water heater.
6. Remove the “RED” color coded L.P. orifice and pilot assembly and replace
with natural gas orifice and pilot assembly provided in the cloth bag
attached to the water heater.
7. Replace the burner assembly, reconnect all fittings and check for leaks.
Refer to “Gas Connections”, page 15.
8. Close and/or replace inner and outer doors.
9. To light pilot, follow the lighting instructions provided on the water heater
and in this installation and operation instruction manual.
10. Remove “equipped for” card from cloth bag and attach to gas piping as
close to gas control as possible. Remove and discard tag attached to
water inlet fitting of the water heater.
17