Specifications

Venting Specifications for:

40 Gallon

50 Gallon
60 Gallon

Through the Wall

Terminating

# of

Elbows

Maximum Straight

Length ft (m)

Minimum Straight

Length ft (m)

2" Diameter (5.1 cm) PVC Vent Connector Lengths

1

45 (13.7)

2 (.6)

Through the Wall

2

40 (12.2)

2 (.6)

Through the Wall

3

35 (10.7)

2 (.6)

Through the Wall

4

30 (9.2)

2 (.6)

Through the Wall

Terminating

# of

Elbows

Maximum Straight

Length ft (m)

Minimum Straight

Length ft (m)

3" Diameter (7.6 cm) PVC Vent Connector Lengths

1

115 (35.0)

10 (3.1)

Through the Wall

2

110 (33.5)

10 (3.1)

Through the Wall

3

105 (32.0)

10 (3.1)

Through the Wall

4

100 (30.5)

10 (3.1)

Through the Roof

0

50 (15.2)

7 (2.1)

Through the Roof

1

45 (13.7)

7 (2.1)

Through the Roof

2

40 (12.2)

7 (2.1)

Through the Roof

3

35 (10.7)

7 (2.1)

Through the Roof

0

120 (36.6)

15 (4.6)

Through the Roof

1

115 (35.0)

15 (4.6)

Through the Roof

2

110 (33.5)

15 (4.6)

Through the Roof

3

105 (32.0)

15 (4.6)

Through the Wall

5

95 (29.0)

10 (3.1)

Through the Roof

4

100 (30.5)

18 (5.5)