beautypg.com

Remove blower to gain access to flue baffle – Bradford White M-2-TW-75T6BN User Manual

Page 33

background image

TTW SERVICE PROCEDURE XII

Flue Baffle

Inspection and replacement

Step 1.

Position gas control power switch to the “OFF” position
and unplug blower from wall outlet.

Step 2.

Disconnect vent system from exhaust adapter on top of
blower.

Step 3.

Unplug cord sets from blower. (see photo 33).

Step 4.

Remove the three blower mounting screws
(¼" nut driver) (see photo 33).

Step 5.

Remove blower with gasket from water heater.

Step 6.

Remove flue baffle from Heater (see photo 34).

Step 7.

Inspect baffle for deterioration, missing restrictors.
Clean any scale or debris build up. Replace with new
baffle as necessary.

Step 8.

Reinstall baffle into flue tube. Be sure baffle
hanger tab are inserted into notch location at the
top of the flue tube (see photos 35 & 36).

Step 9

Check Burner to insure no scale has accumulated during
this operation. See burner cleaning procedure on page 15.

Step 10.

Reinstall blower on water heater. Connect vent
system and cord sets to blower. Plug water heater
into wall outlet.

Step 11.

To resume operation follow the lighting instruction
located on the lighting instruction label or the lighting
instruction located in the installation and operation
manual.

Blower Mounting

Screws

Blower

Cord Sets

33

Disconnect vent

system from exhaust

adapter.

Remove blower to gain access to
flue baffle

Flue Baffle

Flue tube

notch

Baffle shown

installed in flue

tube notch.

Page 33

34

35

36

Page 33

33