TTW SERVICE PROCEDURE IX

115 VAC Trace

WARNING

115 volt potential exposure. Use caution

making voltage checks to avoid personal injury.

Disconnect cord set as

shown in photo 28

LED status

None, Control LED not

on or flashing.

Step 1.

Verify 115VAC and proper polarity at wall outlet.

Step 2.

With unit plugged in and control power switch in the “ON” position verify LED status.

LED status

Short flash, once every

four seconds.

LED status

“Heartbeat”, alternates

bright/dim.

LED status

Various flashing error

codes.

Waiting for

call for heat.

Thermostat calling

for heat

Verify error code as

listed on page 13

Using a volt meter set

to volts AC, is there

115VAC across

terminals shown in

photo 29 ?

N

Y

28

29

Reconnect cord set

shown in photo 28.

Repair damage

Check for damage to

AC supply power cord.

Y

N

Replace Blower

32

Check for 115VAC between black & white wires.

-NOTE-

Electronic meter probes required. Use care not to

damage connector during this check.

Wire sheath pulled back to

identify wire colors

31

Wire harness

Disconnect wire harness

from gas control

(see photo 31).

Locate black & white wires at

connector, It may be necessary to pull

back wire sheath to identify wire colors.

(see photo 32)

Y

N

Replace gas

control.

Is there 115VAC

across black & white

wires as shown in

photo 32?

Call for technical

support.

Is there 115VAC
across terminals

shown in photo 30 ?

N

Y

Incorrect supply

voltage polarity

30

Page 30

115 VAC Circuit Trace

Page 30

30