beautypg.com

Integrated mixing device - imd specifications – Bradford White TW-55X-78B-3X User Manual

Page 2

background image

Mixed water supply temperature range

INTEGRATED MIXING DEVICE - IMD SPECIFICATIONS

100 - 145°F (38 - 63°C)

Water heater outlet temperature range

100 - 180°F (38 - 82°C)

Temperature differential
(between hot supply and outlet temperature)

Device temperature stability (nominal)

± 3°F (± 1.7°C) at 3 - 5 gpm (see note 1)
± 5°F (± 3.0°C) at 5 - 40 gpm (see note 1)

Cold water inlet temperature range

33 - 80°F (1 - 27°C)

Hydrostatic pressure

150 psi (1034 kPa) maximum

27°F (15°C) (see note 2)

± 10% (see note 3)

0.25 gpm (0.9 L/m)

19.2 gpm (72.0 L/m)

2.8 (mixed temp. of 95°F)
1.8 (mixed temp. of 120°F)
1.3 (mixed temp. of 140°F)

Permitted supply pressure variation

Flow rate (min)

Flow rate (max)

Cv

Notes:
1. As tested in accordance with ASSE 1017.
2. This is the minimum difference required between the mixed water supply temperature and the

water heater outlet temperature to enable the IMD to function correctly and ensure shut-off of
outlet flow in the event of cold supply failure.

3. Maximum permitted variation in either supply pressure in order to control the mixed water supply

temperature to within ± 3°F. Excessive changes in supply pressures may cause changes in
mixed water supply temperature.

Page 2

Table 1

5

10

20

30

40

50

60

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Flow (gpm)

P

re

s

su

re

D

ro

p

(p

si

)

Mixed Temperature

of 95°F

of 120°F

of 140°F

Mixed Temperature

Mixed Temperature