beautypg.com

Programming, Setting the operating ranges – B&C Technologies EDG Dryer Control (DE, DP, DI Series) User Manual

Page 8

background image

Setting the operating ranges

The password required to access this phase is “916”. Proceed as follows : press both keys UP and

1 at the same time. The message “PASSWO” is now displayed, then press ENTER.

The display now shows “00000”. Press the DOWN key three times to erase three zeroes starting

from the right and then type in the password “916”. Press ENTER. Actual programming starts now.

DISPLAY

ALLOWED VALUES

DESCRIPTION

CELSIUS SN

Yes/No

Yes - Programs and displays in Celsius.
No - Programs and displays in Fahrenheit.

ANTICREASE
SN

Yes/No

Anti-creases. Enables or disables the anti-wrinkle feature at
the end of the program.

CYCLE TIME

0..99 (min)

Cycle time.
This parameter specifies duration of the drying cycle.

T ROTATION

10..200 (sec)

Rotation time (only if reversing is enabled).
This parameter indicates the maximum duration in seconds
of rotation entered in the programs.

T PAUS

10..250 (sec)

Rotation pause time (only if reversing is enabled)
This parameter indicates the minimum time that the basket
must stop for between one motion reversal and the next.

° HEAT

30..99 (°C)

Heating temperature.
Establishes the maximum temperature value that can be
programmed.

TIME COOL

0..15 (min)

Cooldown time.
This parameter sets the maximum duration of the cool down
time for each individual program.

°COOLING

20..50 (°C)

Cool down temperature.
The maximum temperature that can be set for each program
in order to consider cool down finished.

Programming

8