Restart after a power failure
Specific behavior of the single cycle
Password list
In case a power failure occurs while a program is
running, the following information will be stored
in memory : number of the program under way,
the residual time, the phase under way and any
other data required to restore the operating
conditions in force right before the power failure.
When the power supply is restored, the display
indicates the program interrupted, and the user
can press ENTER to start it or STOP to stop it for
good.
The execution of a single cycle is rather simple
compared to that of a complete program. In case
of single cycle, a group of settings is carried out
using standard values (not set by the user),
namely:
The basket rotation time is set for 20 seconds
Pause time during basket rotation is also 20
seconds
The cooling down phase lasts 5 minutes or
until a temperature of 35°C is reached
At the end of the program the buzzer goes off
for 2 seconds
The anti-crease cycle is not carried out at the
end of the program
Following is a list of available passwords and
their purpose:
CODE
FUNCTION
748
Access to Machine Configuration
916
Access to Operating Ranges
955
Access to Cycle Programming
750
Reset control to defaults
383
Access to test procedure
743
Display working hour counter
347
Reset working hour counter
666
Set to on signal for reset gas control unit
667
Set to off signal for reset gas control unit