Maintenance, Basic troubleshooting, Control problems – B&C Technologies IS Series Commercial Ironer User Manual
Page 31: Belt problems, Chapter 5 maintenance, 1 basic troubleshooting

Chapter 5
Maintenance
5.1
Basic Troubleshooting
5.1.1
Control Problems
Temperature Control shows S.Err
Indicates an input error. Check the input wiring for bad connections and short-circuits.
Temperature Control shows E111
Indicates a memory error. Turn the machine power off, then back on. If the display continues to
show the error, contact a qualified service technician.
Temperature Control shows cccc
Damaged sensor or wiring. Repair or replace.
Speed Display shows n1.Err, n2.Err, n3.Err, Err-o, or CHG-o
Indicates a memory error. Turn the machine power off, then back on. If the display continues to
show the error, contact a qualified service technician.
5.1.2
Belt Problems
The ironing belts will shrink under 3 conditions:
1. if they are installed with the wrong side to the heated cylinder (Gold side should face cylin-
der)
2. if they are taken off the machine when they are hot
3. if they are overheated by not spreading out small piece work across the cylinder
28