INPUT CHARACTERISTICS:
GSM-6550P/6600P(G1)
VOLTAGE: 90 ~ 264 VAC FULL RANGE.
FREQUENCY: 47 ~ 63 Hz.
INPUT CURRENT: 9.0/10.0 A FOR 115 VAC, 4.5/5.0 A FOR 230 VAC.
INRUSH CURRENT: 65 A MAX. FOR 115 VAC, 125 A MAX. FOR 230 VAC.
OUTPUT CHARACTERISTICS:
LOAD LINE
RIPPLE & NOISE
MAX.[P-P]
5V
3%
1%
60mV
12V
3%
1%
100mV
5%
1%
100mV
5%
1%
100mV
3.3V
3%
1%
60mV
+5VSB
5%
1%
60mV
REMARK: +5V and +3.3V Max. Current: 50A
+12V TOTAL OUTPUT MAX. 40A.
TOTAL OUTPUT SHOULD NOT EXCEED 550W/600W FOR GSM-6550P/6600P.
*** WHEN PERFORMING CROSS REGULATION TEST, IT IS REQUESTED TO SET THE HIGHER OUTPUT
CHANNEL AT 90% MAXIMUM AND THE LOWER OUTPUT CHANNELS AT 20% MININUM OF RATED
SPEC.
TEMPERATURE RANGE: OPERATING 0
0
C --- 50
0
C, STORAGE –20
0
C --- 70
0
C.
HUMIDITY: 10 ~ 90 % RH.
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE.
DIELECTRIC WITHSTANDING VOLTAGE:
PRIMARY TO SECONDARY: 1800VAC FOR 1 SEC.
PRIMARY TO FG: 1800VAC FOR 1 SEC.
EFFICIENCY: 70% TYPICAL, AT FULL LOAD, 115VAC.
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms.
OVER LOAD PROTECTION: 110 ~ 150% MAX.
OVER CURRENT PROTECTION:
+5V
33 A ~ 45 A, + 3.3V
33 A ~ 45 A, 12V
44 A ~ 66A
OVER VOLTAGE PROTECTION:
+5V
5.7V ~ 6.2V, 3.3V
3.7V ~ 4.1V, 12V
13.3V ~ 14.3V
EMI: MEET FCC CLASS B, CISPR22 CLASS B.
SAFETY: UL 60950, CSA 22.28 NO950-95, TÜV EN-60950.
ACTIVE POWER FACTOR CORRECTION MEET IEC-1000-3-2 CLASS D
REMOTE ON / OFF CONTROL.
SHORT CIRCUIT PROTECTION: SHUTDOWN AND LATCH.
BUILT-IN ACTIVE POWER FACTOR CORRECTOR.
COOLING: ONE 80 mm DC BALL BEARING FAN.
DIMENSION: 86(H) X 150(W) X 160 (D) mm (STRETCH PS/2, EPS12V).